DP4500/3500 TROUBLESHOOTING
5 - 86
December 2000 © TOSHIBA TEC
[CC4] Swing motor is abnormal
MJ-1012/1013 (Finishier section)
[Procedure 1]
Rotate the swing motor in reverse by hand. Does the swing guide move up and down?
NO
Fix the swing mechanism.
YES
Is the swing guide closed detection switch-2 (MS6) working normally?
NO
Replace the switch.
YES
Is the swing guide open sensor (PI18) working normally?
NO
Replace the sensor.
YES
Is the swing motor (M7) rotating in reverse at the fixed timing?
NO
Replace the motor.
YES
END
[Procedure 2]
Is the safety zone switch (MS3) working normally?
NO
Replace the switch.
YES
Is the safety zone switch (MS3) correctly pressed?
NO
Fix the mechanism.
YES
Is the swing guide closed detection switch-2 (MS6) working normally?
NO
Replace the switch.
YES
Is the swing guide closed detection switch-2 (MS6) correctly pressed?
NO
Fix the mechanism.
YES
Replace the finisher controller PC board.
▼
▼
▼
▼
▼
▼▼▼▼▼
▼
▼
▼
▼
▼
▼▼▼▼▼
▼
▼
▼
▼
▼
▼▼▼▼▼
▼
▼
▼
▼
▼
▼▼▼▼▼
▼
▼
▼
▼
▼
▼▼▼▼▼
▼
▼
▼
▼
▼
▼▼▼▼▼
▼
▼
▼
▼
▼
▼▼▼▼▼
▼
▼
▼
▼
▼
▼▼▼▼▼