G005790
1
2
3
4
4
Figure 13
1.
Main tank lid
3.
Drill point
2.
Tank ridge, back and right
of lid
4.
6.4 cm (2-1/2 inches)
Note:
Place a receptacle inside the tank and below
the area to be drilled to catch any debris created
during the drilling process.
Important:
Debris left inside a tank could clog
and damage the spray system during operation.
4. Drill a 3.5 cm (1-3/8 inch) diameter hole in the tank
at the spot marked previously (Figure 13).
5. Use a blade to clean the plastic burrs and excess
material from the hole drilled.
6. Clean any debris from the drilling process left inside
the tank.
Assembling the Rinse Nozzle
1. Snap a threaded fitting over one end of the rinse
tube as shown in Figure 14.
Important:
Do not
install threaded fittings on
both ends of the rinse tube at this time.
1
2
3
G005791
Figure 14
1.
Rinse tube
3.
Rinse nozzle bulb
2.
Threaded fitting
2. Install the rinse nozzle bulb over the threaded side
of the rinse tube (Figure 14).
Installing the Rinse Nozzle
1. Locate the rinse nozzle bulkhead in loose parts. If
the bulkhead is shipped assembled, disassemble as
shown in Figure 15.
A. Remove the plastic ring nut from the bulkhead.
B. Push the large, clear O-ring on the bulkhead up
flush to the flange fitting to keep it seated.
C. Remove the large retainer nut and O-ring
D. Retain all parts.
G005792
4
5
1
3
2
4
5
1
3
2
Figure 15
1.
Bulkhead fitting
4.
Retainer nut, large
2.
Plastic ring nut
5.
O-ring, small black
3.
O-ring, large clear
2. Install the bulkhead fitting with the seal facing down
into the hole drilled in the main tank (Figure 16).
Important:
Ensure that the seal is seated
correctly between the bulkhead flange and the
tank surface (Figure 16).
1
2
3
4
5
6
G005793
Figure 16
1.
Bulkhead
4.
Main tank
2.
Flange, bulkhead
5.
Threaded end, bulkhead
3.
O-ring, clear
6.
Plastic ring nut
3. Secure the fitting and seat the seal by installing the
plastic ring nut to the threads of the fitting in the
tank interior and hand tightening (Figure 16).
4. Install assembled rinse nozzle and tube up through
the bulkhead fitting installed in the main tank
(Figure 17).
9