5.5.
Machine stop
5.5.1.
Normal stop
In normal operating conditions:
▪
By releasing the controls the operation is stopped. Stop occurs within a time limit set in the factory, which guarantees
smooth braking.
▪
By releasing the dead-man pedal located on the platform, the operation is immediately stopped. In the event of an
immediate stop, braking is sudden.
5.5.2.
Emergency stop
Should it be necessary, the operator may immediately stop all machine functions on both platform and ground control panel.
On the platform control panel:
▪
press the emergency stop button on the control panel and the machine is turned off.
▪
By releasing the dead-man pedal, the operation is immediately stopped. In the event of an immediate stop, braking is
sudden.
On the ground control panel:
▪
Press the emergency stop button and the machine (all models) and the heat engi
ne (models “D”, “ED”, “EB”) are
stopped.
▪
Press the power emergency stop button (if available
–
“E” models), and the machi
ne power (power circuit cut-out) is
cut-out.
To resume the operations is necessary:
On the platform control panel:
▪
Turn the emergency stop button of 1/4 turn clockwise.
On the ground control panel:
▪
Turn the emergency stop button of 1/4 turn clockwise.
▪
Pull the power circuit emergency stop button (if available) to the outside until it locks in position to power the machine
again.
5.5.3.
Diesel engine stop
In order to stop the Diesel engine:
On the platform control panel:
▪
Turn the starter key antic
lockwise to position “0”.
▪
Otherwise, press the emergency stop button.
On the ground control panel:
▪
Turn the starter key anticlockwise to position “0”.
▪
Otherwise, press the emergency stop button.
Do not stop the motor when the r.p.m. is high. Before stopping the motor wait until the r.p.m. is at the
lowest.
5.5.4.
Stopping the 380V three-phase or 230V single-phase electrical pump (optional)
To stop the electrical pump (optional):
On the platform control panel:
▪
Press the stop button.
▪
Otherwise, press the emergency stop button.
On the ground control panel:
▪
Press the emergency stop button.
Содержание AIRO A Series
Страница 14: ...Use and Maintenance Manual A16 J A18 J Series Page 14...
Страница 17: ...Use and Maintenance Manual A16 J A18 J Series Page 17...
Страница 20: ...Use and Maintenance Manual A16 J A18 J Series Page 20...
Страница 23: ...Use and Maintenance Manual A16 J A18 J Series Page 23...
Страница 26: ...Use and Maintenance Manual A16 J A18 J Series Page 26...
Страница 29: ...Use and Maintenance Manual A16 J A18 J Series Page 29...
Страница 89: ...Use and Maintenance Manual A16 J A18 J Series Page 89...
Страница 108: ...Use and Maintenance Manual A16 J A18 J Series Page 108 029 08 144...
Страница 109: ...Use and Maintenance Manual A16 J A18 J Series Page 109 029 08 149...
Страница 110: ...Use and Maintenance Manual A16 J A18 J Series Page 110 029 08 161...
Страница 111: ...Use and Maintenance Manual A16 J A18 J Series Page 111 029 08 171...
Страница 112: ...Use and Maintenance Manual A16 J A18 J Series Page 112 029 08 128...
Страница 113: ...Use and Maintenance Manual A16 J A18 J Series Page 113 029 08 129...
Страница 114: ...Use and Maintenance Manual A16 J A18 J Series Page 114 029 08 150...
Страница 115: ...Use and Maintenance Manual A16 J A18 J Series Page 115 029 08 132...
Страница 116: ...Use and Maintenance Manual A16 J A18 J Series Page 116 029 08 158...
Страница 117: ...Use and Maintenance Manual A16 J A18 J Series Page 117 029 08 148...
Страница 118: ...Use and Maintenance Manual A16 J A18 J Series Page 118 029 08 147...
Страница 119: ...Use and Maintenance Manual A16 J A18 J Series Page 119...
Страница 121: ...Use and Maintenance Manual A16 J A18 J Series Page 121...
Страница 123: ...Use and Maintenance Manual A16 J A18 J Series Page 123...