The system needs calibration:
▪
In case of replacement of one of the items composing the system.
▪
When, following an excessive overload or a collision, without the excessive load the danger condition is signalled
anyway.
Calibration depends on the type of fitted device.
If the board is the one shown in
fig.30a
:
▪
switch off the machine;
▪
open the box
C
which contains electronic board
;
▪
without any load on the platform, fit the bridge between the two pins of the connector
G
;
▪
switch on the machine;
▪
press button
D
(the yellow light and red light turn on);
▪
press button
E
(the luminosity of the red light increases a few seconds), and the overload controller will be reset;
▪
position a distributed load on the platform equal to nominal capacity plus 20% ;
▪
press button
F
(the green light turns on a few seconds) to store the overload condition;
▪
press button
D
again to exit the calibration procedure (the yellow light turns off and if the procedure has been carried
out correctly, the red light stays on signalling the overload);
▪
switch off the machine;
▪
open the jumper on connector
G
;
▪
switch on the machine;
▪
check that after removing the 20% overload (only the rated load remains on the platform) the alarm condition does not
occur in any of the platform positions (platform down, up, driving, rotated);
▪
Once the adjustment has been completed, close the box which contains the board.
If the board is the one shown in
fig.30b
:
▪
switch off the machine;
▪
Open the box which contains electronic board.
▪
switch on the machine;
▪
With no load on the platform, press and hold buttons
1
and
4
until the word
CONS
appears;
▪
Press
4
to enter the
CAP
and
4
again to display the parameter value;
▪
Enter the correct value =
1000
via the button
1
,
2
and
3
. Press button
4
to save and exit.
▪
Press
2
and
2
again
to switch to
J01J
, press
4
to display the parameter value;
▪
Enter the correct value =
1
via the button
1
, and
2
. Press button
4
to save and exit.
▪
Press
3
and
2
again to switch to
CALB
. Press
4
to switch to
CAL
;
▪
After checking that there are no loads on platform, press
1
to perform the zero calibration;
▪
Load the weight equal to the nominal load and check out the value shown on the display. If it is correct, press
4
to save
and exit, otherwise press
2
and then, via buttons
1
,
2
and
3
manually enter the correct value. Press
4
and
4
again to
go back to
CALB
.
▪
Press
2
and
2
again to switch to
ALAR
, then press
4
and
2
again to switch to
BLOC
;
▪
Press
4
to enter and then, via buttons
1
,
2
and
3
, enter the alarm value equal to the nominal load + the overload of
20%. Press
4
to save;
▪
Press
2
to go to
DIFF
and
4
again to enter. Set the value =
0045
, via buttons
1
,
2
and
3
, then 4 again to store;
▪
Press
2
to switch to
TEST
and
4
again to do the test. When
PASS
appears, press
3
three times
to exit calibration;
▪
Check out if the display shows the value of the current load on the platform;
▪
Check out if with a load >= the rated load + 20% overload, the system goes into overload alarm and that, by removing
the 20% overload, the alarm condition disappears;
▪
Once the adjustment has been completed, close the box which contains the board.
AS THIS OPERATION IS VERY IMPORTANT IT IS TO BE CARRIED OUT BY SKILLED TECHNICIANS ONLY
Содержание AIRO A Series
Страница 14: ...Use and Maintenance Manual A16 J A18 J Series Page 14...
Страница 17: ...Use and Maintenance Manual A16 J A18 J Series Page 17...
Страница 20: ...Use and Maintenance Manual A16 J A18 J Series Page 20...
Страница 23: ...Use and Maintenance Manual A16 J A18 J Series Page 23...
Страница 26: ...Use and Maintenance Manual A16 J A18 J Series Page 26...
Страница 29: ...Use and Maintenance Manual A16 J A18 J Series Page 29...
Страница 89: ...Use and Maintenance Manual A16 J A18 J Series Page 89...
Страница 108: ...Use and Maintenance Manual A16 J A18 J Series Page 108 029 08 144...
Страница 109: ...Use and Maintenance Manual A16 J A18 J Series Page 109 029 08 149...
Страница 110: ...Use and Maintenance Manual A16 J A18 J Series Page 110 029 08 161...
Страница 111: ...Use and Maintenance Manual A16 J A18 J Series Page 111 029 08 171...
Страница 112: ...Use and Maintenance Manual A16 J A18 J Series Page 112 029 08 128...
Страница 113: ...Use and Maintenance Manual A16 J A18 J Series Page 113 029 08 129...
Страница 114: ...Use and Maintenance Manual A16 J A18 J Series Page 114 029 08 150...
Страница 115: ...Use and Maintenance Manual A16 J A18 J Series Page 115 029 08 132...
Страница 116: ...Use and Maintenance Manual A16 J A18 J Series Page 116 029 08 158...
Страница 117: ...Use and Maintenance Manual A16 J A18 J Series Page 117 029 08 148...
Страница 118: ...Use and Maintenance Manual A16 J A18 J Series Page 118 029 08 147...
Страница 119: ...Use and Maintenance Manual A16 J A18 J Series Page 119...
Страница 121: ...Use and Maintenance Manual A16 J A18 J Series Page 121...
Страница 123: ...Use and Maintenance Manual A16 J A18 J Series Page 123...