Vanquish Diode Array Detectors (VH-D10) Operating Manual
Type
Specification
Materials in the flow path
See the
Specifications
for the flow cells.
NOTICE
For information about the chemical resistance of materials
refer to the technical literature.
Solvent and additive information
See
Safety features
Power-up check of optics, cooling fans, motors and electronics
Leak detection and safe leak handling
Good Laboratory Practice (GLP)
features
Predictive Performance functions for scheduling maintenance
procedures based on the actual operating and usage conditions of
the detector.
This includes monitoring of lamp age, lamp ignitions and lamp
intensity.
All system parameters are logged in the Chromeleon Audit Trail.
Temperature reference conditions for noise, drift and linearity specifications
For drift tests, ASTM requires that temperature changes stay below
2 °C/hour over a period of one hour. The drift specification above is
based on these conditions. Larger changes in the ambient temperature
will result in a larger drift.
For best performance, minimize the frequency and the amplitude of
changes in the ambient temperature to 1 °C/hour.
All performance tests should be done with a completely warmed up
optical unit (lamp turned on for more than two hours). ASTM requires
that the detector should be turned on for at least 24 hours before the
testing is started.
TIP
LightPipe flow cells may show an increased drift for several hours
after storage, contamination, or if the flow was stopped for some time.
Consider this when testing the drift specification of the detector.
Time constant and response time
According to ASTM E1657-98, the time constant is converted to the
response time by multiplying by the factor 2.2 (i.e., response time =
2.2 x time constant).
Содержание Vanquish VH-D10
Страница 4: ...Contacting Us Page 4 Vanquish Diode Array Detectors VH D10 Operating Manual...
Страница 44: ...4 Unpacking Page 44 Vanquish Diode Array Detectors VH D10 Operating Manual...
Страница 80: ...5 Installation Page 80 Vanquish Diode Array Detectors VH D10 Operating Manual...
Страница 110: ...6 Operation Page 110 Vanquish Diode Array Detectors VH D10 Operating Manual...
Страница 162: ...7 Maintenance and Service Page 162 Vanquish Diode Array Detectors VH D10 Operating Manual...
Страница 190: ...11 Appendix Page 190 Vanquish Diode Array Detectors VH D10 Operating Manual...
Страница 191: ...12 Index Vanquish Diode Array Detectors VH D10 Operating Manual Page 191 12 Index...
Страница 195: ...12 Index Vanquish Diode Array Detectors VH D10 Operating Manual Page 195...
Страница 196: ...Thermo Fisher Scientific Inc 168 Third Avenue Waltham Massachusetts 02451 USA www thermofisher com...