ADC10_B Registers
Table 16-4. ADC10CTL1 Register Description (continued)
Bit
Field
Type
Reset
Description
4-3
ADC10SSELx
RW
0h
ADC10_B clock source select
Can be modified only when ADC10ENC = 0. Resetting ADC10ENC = 0 by
software and changing these fields immediately shows effect also when a
conversion is active.
00b = MODCLK
01b = ACLK
10b = MCLK
11b = SMCLK
2-1
ADC10CONSEQx
RW
0h
ADC10_B conversion sequence mode select
Can be modified only when ADC10ENC = 0. Resetting ADC10ENC = 0 by
software and changing these fields immediately shows effect also when a
conversion is active.
00b = Single-channel, single-conversion
01b = Sequence-of-channels
10b = Repeat-single-channel
11b = Repeat-sequence-of-channels
0
ADC10BUSY
R
0h
ADC10_B busy. This bit indicates an active sample or conversion operation.
0b = No operation is active.
1b = A sequence, sample, or conversion is active
.
453
SLAU272C – May 2011 – Revised November 2013
ADC10_B Module
Copyright © 2011–2013, Texas Instruments Incorporated