Instruction Set Description
4.6.2.10 CLR
* CLR[.W]
Clear destination
* CLR.B
Clear destination
Syntax
CLR dst
or
CLR.W dst
CLR.B dst
Operation
0
→
dst
MOV #0,dst
Emulation
MOV.B #0,dst
Description
The destination operand is cleared.
Status Bits
Status bits are not affected.
Example
RAM word TONI is cleared.
CLR
TONI
; 0 -> TONI
Example
Register R5 is cleared.
CLR
R5
Example
RAM byte TONI is cleared.
CLR.B
TONI
; 0 -> TONI
143
SLAU272C – May 2011 – Revised November 2013