ADC10_B Registers
16.3.1 ADC10CTL0 Register
ADC10_B Control Register 0
Figure 16-12. ADC10CTL0 Register
15
14
13
12
11
10
9
8
Reserved
ADC10SHTx
r0
r0
r0
r0
rw-(0)
rw-(0)
rw-(0)
rw-(0)
7
6
5
4
3
2
1
0
ADC10MSC
Reserved
ADC10ON
Reserved
ADC10ENC
ADC10SC
rw-(0)
r0
r0
rw-(0)
r0
r0
rw-(0)
rw-(0)
Can be modified only when ADC10ENC = 0. Resetting ADC10ENC = 0 by software and changing these fields
immediately shows effect also when a conversion is active.
Table 16-3. ADC10CTL0 Register Description
Bit
Field
Type
Reset
Description
15-12
Reserved
R
0h
Reserved. Always reads as 0.
11-8
ADC10SHTx
RW
0h
ADC10_B sample-and-hold time. These bits define the number of ADC10CLK
cycles in the sampling period for the ADC10.
Can be modified only when ADC10ENC = 0. Resetting ADC10ENC = 0 by
software and changing these fields immediately shows effect also when a
conversion is active.
0000b = 4 ADC10CLK cycles
0001b = 8 ADC10CLK cycles
0010b = 16 ADC10CLK cycles
0011b = 32 ADC10CLK cycles
0100b = 64 ADC10CLK cycles
0101b = 96 ADC10CLK cycles
0110b = 128 ADC10CLK cycles
0111b = 192 ADC10CLK cycles
1000b = 256 ADC10CLK cycles
1001b = 384 ADC10CLK cycles
1010b = 512 ADC10CLK cycles
1011b = 768 ADC10CLK cycles
1100b = 1024 ADC10CLK cycles
1101b = 1024 ADC10CLK cycles
1110b = 1024 ADC10CLK cycles
1111b = 1024 ADC10CLK cycles
7
ADC10MSC
RW
0h
ADC10_B multiple sample and conversion. Valid only for sequence or repeated
modes.
Can be modified only when ADC10ENC = 0. Resetting ADC10ENC = 0 by
software and changing these fields immediately shows effect also when a
conversion is active.
0b = The sampling timer requires a rising edge of the SHI signal to trigger each
sample-and-convert.
1b = The first rising edge of the SHI signal triggers the sampling timer, but further
sample-and-conversions are performed automatically as soon as the prior
conversion is completed.
6-5
Reserved
R
0h
Reserved. Always reads as 0.
4
ADC10ON
RW
0h
ADC10_B on
Can be modified only when ADC10ENC = 0. Resetting ADC10ENC = 0 by
software and changing these fields immediately shows effect also when a
conversion is active.
0b = ADC10_B off
1b = ADC10_B on
3-2
Reserved
R
0h
Reserved. Always reads as 0.
450