Quit Current
(–)
Quit Current
Current
Time
RELAX Mode
CHARGE Mode
DISCHARGE Mode
RELAX Mode
CHARGE Mode
DISCHARGE Mode
RELAX Mode
Chg Relax Time
Dsg Relax Time
1
1
0
1
1
1
0
[DSG]
Introduction
61
SLUUBD3D – September 2015 – Revised September 2018
Copyright © 2015–2018, Texas Instruments Incorporated
CEDV Gas Gauging
Figure 9-2. Fuel Gauge Operating Mode Example
Class
Subclass
Name
Format
Size in
Bytes
Min
Max
Default
Unit
Fuel
Gauging
Current
Thresholds
Dsg Current
Threshold
Unsigned
Integer
2
0
2000
100
mA
Fuel
Gauging
Current
Thresholds
Dsg Relax
Time
Unsigned
Integer
1
0
255
1
s
Fuel
Gauging
Current
Thresholds
Chg Current
Threshold
Unsigned
Integer
2
0
2000
50
mA
Fuel
Gauging
Current
Thresholds
Chg Relax
Time
Unsigned
Integer
1
0
255
60
s
Fuel
Gauging
Current
Thresholds
Quit Current
Unsigned
Integer
2
0
1000
10
mA
9.1.3 Full Charge Capacity
Class
Subclass
Name
Format
Size in
Bytes
Min
Max
Default
Unit
Fuel
Gauging
State
Learned Full
Charge
Capacity
Unsigned
Integer
2
0
65535
4400
mAh or 10
mWh