0x2E VAUXVoltage()
136
SLUUBD3D – September 2015 – Revised September 2018
Copyright © 2015–2018, Texas Instruments Incorporated
SBS Commands
1 = High
0 = Low
LED4 (Bit 4)
: GPIO 4
1 = High
0 = Low
LED3 (Bit 3)
: GPIO 3
1 = High
0 = Low
LED2 (Bit 2)
: GPIO 2
1 = High
0 = Low
LED1 (Bit 1)
: GPIO 1
1 = High
0 = Low
RSVD (Bit 0)
: Reserved
17.38 0x2E VAUXVoltage()
This read-word function returns an unsigned integer value representing the scaled measured voltage from
the VAUX pin, in units of mV if
[VAUX_SCALE]
= 0, and 10 mV if
[VAUX_SCALE]
= 1 with a range of 0
to 65535. The returned value = VAUX ×
VAUX Gain
.
SBS
Cmd
Name
Access
Protocol
Type
Min
Max
Unit
Note
SE
US
FA
0x2E
VAUXVoltage()
R
R
R
Word
U2
—
—
—
The value of
VAUX Gain
is stored in the following data flash.
Class
Subclass
Name
Type
Min
Max
Default
Unit
Calibration
Voltage
VAUX Gain
U4
0
65535
5000
—
17.39 0x2F Authenticate()/ManufacturerInput()
This read-/write-block function provides SHA-1 authentication in the default mode. It is also used to
perform data flash read/writes in DATA FLASH ACCESS mode.
SBS
Cmd
Name
Access
Protocol
Type
Min
Max
Unit
Note
SE
US
FA
0x2F
Authenticate()
R/W
R/W
R/W
Block
H20+1
—
—
—
SBS
Cmd
Name
Access
Protocol
Type
Min
Max
Unit
Note
SE
US
FA
0x2F
ManufacturerInput()
R/W
R/W
R/W
Block
H32
—
—
—
17.40 0x30..0x3E CellVoltage1..15()
These read-word functions return an unsigned value of the calculated individual cell voltages, in mV, with
a range of 0 to 65535.
CellVoltage1()
corresponds to the bottom-most series cell element, while
CellVoltage15()
corresponds to the top-most series cell element.