Temperature Protections
29
SLUUBD3D – September 2015 – Revised September 2018
Copyright © 2015–2018, Texas Instruments Incorporated
Protections
3.7.2 Overtemperature in Discharge Protection
The device has an overtemperature protection for cells in DISCHARGE state (that is, non-charging state
with
BatteryStatus[DSG]
= 1).
Status
Condition
Action
Normal
Cell Temperature in
Temperatures() <
OTD:Threshold
OR charging
SafetyAlert()[OTD]
= 0
Alert
Cell Temperature in
Temperatures()
≥
OTD:Threshold
AND not charging (that is,
BatteryStatus[DSG]
= 1)
SafetyAlert()[OTD]
= 1
Trip
Cell Temperature in
Temperatures()
≥
OTD:Threshold
AND not charging (that is,
BatteryStatus[DSG]
= 1) for
OTD:Delay
duration
SafetyAlert()[OTD]
= 0
SafetyStatus()[OTD]
= 1
BatteryStatus()[OTA]
= 1
Discharging is disabled AND
OperationStatus()[XDSG]
=
1 if
FET Options[OTFET]
= 1.
Recovery
SafetyStatus()[OTD]
AND Cell Temperature in
Temperatures()
≤
OTD:Recovery
SafetyStatus()[OTD]
= 0
BatteryStatus()[OTA]
= 0
Discharging is allowed AND
OperationStatus()[XDSG]
=
0 if
FET Options[OTFET]
= 1.
Class
Subclass
Name
Type
Min
Max
Default
Unit
Protections
OTD
Threshold
I2
–400
1500
600
0.1°C
Protections
OTD
Delay
U1
0
255
2
s
Protections
OTD
Recovery
I2
–400
1500
550
0.1°C
3.7.3 Undertemperature in Charge Protection
The device has an undertemperature protection for cells in charge direction (that is, with
BatteryStatus[DSG]
= 0).
Status
Condition
Action
Normal
Temperature()
>
UTC:Threshold
OR not charging
SafetyAlert()[UTC]
= 0
Alert
Temperature()
≤
UTC:Threshold
AND charging
SafetyAlert()[UTC]
= 1
Trip
Temperature()
≤
UTC:Threshold
AND
Charging for
UTC:Delay
duration
SafetyAlert()[UTC]
= 0
SafetyStatus()[UTC]
= 1
OperationStatus()[XCHG]
= 1
Recovery
SafetyStatus()[UTC]
AND
Temperature()
≥
UTC:Recovery
SafetyStatus()[UTC]
= 0
OperationStatus()[XCHG]
= 0
Class
Subclass
Name
Type
Min
Max
Default
Unit
Protections
UTC
Threshold
I2
–400
1500
0
0.1°C
Protections
UTC
Delay
U1
0
255
2
s
Protections
UTC
Recovery
I2
–400
1500
50
0.1°C
3.7.4 Undertemperature in Discharge Protection
The device has an undertemperature protection for cells in DISCHARGE state (that is, non-charging state
with
BatteryStatus[DSG]
= 1).
Status
Condition
Action
Normal
Temperature()
>
UTD:Threshold
OR charging
SafetyAlert()[UTD]
= 0
Alert
Temperature()
≤
UTD:Threshold
AND
Not charging (that is,
BatteryStatus[DSG]
= 1)
SafetyAlert()[UTD]
= 1
Trip
Temperature()
≤
UTD:Threshold
AND
Not charging (that is,
BatteryStatus[DSG]
= 1) for
UTD:Delay
duration
SafetyAlert()[UTD]
= 0
SafetyStatus()[UTD]
= 1
OperationStatus()[XDSG]
= 1