0x00 ManufacturerAccess() and 0x44 ManufacturerBlockAccess()
115
SLUUBD3D – September 2015 – Revised September 2018
Copyright © 2015–2018, Texas Instruments Incorporated
SBS Commands
1 = EDV2 voltage is reached during discharge.
0 = EDV2 voltage is not reached, or not in DISCHARGE mode.
EDV1 (Bit 13)
: End-of-Discharge Voltage Level 1
1 = EDV1 voltage is reached during discharge.
0 = EDV1 voltage is not reached, or not in DISCHARGE mode.
RSVD (Bits 12–11)
: Reserved. Do not use.
FCCX (Bit 10)
:
FullChargeCapacity()
has been updated. This bit changes state each time
FullChargeCapacity()
updates.
OCVFR (Bit 9)
: Reserved and not used.
REST (Bit 8)
: Rest
1 = OCV Reading Taken
0 = OCV Reading Not Taken or Not in Relax
CF (Bit 7)
: Condition Flag
1 =
MaxError()
> Max Error Limit (Condition Cycle needed)
0 =
MaxError()
< Max Error Limit (Condition Cycle not needed)
DSG (Bit 6)
: Discharge/Relax
1 = Charging Not Detected
0 = Charging Detected
EDV0 (Bit 5)
: End-of-Discharge Voltage Level 0 (Termination)
1 = Termination voltage is reached during discharge.
0 = Termination voltage is not reached, or not in DISCHARGE mode.
BAL_OK (Bit 4)
: Cell Balancing
1 = Cell balancing is possible if enabled.
0 = Cell balancing is not allowed.
TC (Bit 3)
: Terminate Charge
1 = Detected
0 = Not Detected
TD (Bit 2)
: Terminate Discharge
1 = Detected
0 = Not Detected
FC (Bits 1)
: Fully Charged
1 = Detected
0 = Not Detected
FD (Bit 0)
: Fully Discharged
1 = Detected
0 = Not Detected
17.2.41 ManufacturerAccess() 0x0057 ManufacturingStatus
This command returns the
ManufacturingStatus()
flags on
ManufacturerBlockAccess()
or
ManufacturerData()
.
Status
Condition
Action
Activate
0x0057 to
ManufacturerAccess()
Outputs
ManufacturingStatus()
flags on
ManufacturerBlockAccess()
or
ManufacturerData().