0x00 ManufacturerAccess() and 0x44 ManufacturerBlockAccess()
111
SLUUBD3D – September 2015 – Revised September 2018
Copyright © 2015–2018, Texas Instruments Incorporated
SBS Commands
1 = Detected
0 = Not Detected
VIMR (Bit 5)
: Voltage Imbalance while pack is at rest failure
1 = Detected
0 = Not Detected
SOT (Bit 4)
: Safety Overtemperature Cell Failure
1 = Detected
0 = Not Detected
SOCD (Bit 3)
: Safety Overcurrent in Discharge
1 = Detected
0 = Not Detected
SOCC (Bit 2)
: Safety Overcurrent in Charge
1 = Detected
0 = Not Detected
SOV (Bit 1)
: Safety Cell Overvoltage Failure
1 = Detected
0 = Not Detected
SUV (Bit 0)
: Safety Cell Undervoltage Failure
1 = Detected
0 = Not Detected
17.2.38 ManufacturerAccess() 0x0054 OperationStatus
This command returns the
OperationStatus()
flags on
ManufacturerBlockAccess()
or
ManufacturerData()
.
SBS Cmd
Mode
Name
Format
Size in Bytes
Min
Max
Default
Unit
0x0054
R
OperationStatus
Hex
4
0x0000
0x00FF
—
—
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
KEYIN
RSVD
RSVD
CB
SLPCC
SLPAD
RSVD
INIT
SLEEPM
XL
CAL_
OFFSET
CAL
RSVD
AUTH
LED
SDM
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
SLEEP
XCHG
XDSG
PF
SS
SDV
SEC1
SEC0
RSVD
RSVD
SAFE
HCFET
PCHG
DSG
CHG
PRES
KEYIN (Bit 31)
: Indicates the state of the KEYIN input detection and is independent of the [KEY_POL]
setting.
1 = KEYIN has been detected.
0 = KEYIN not been detected.
RSVD (Bits 30–29)
: Reserved. Do not use.
CB (Bit 28)
: Cell balancing status
1 = Active
0 = Inactive
SLPCC (Bit 27)
: CC Measurement in SLEEP mode
1 = Active
0 = Inactive