LED Configuration Register
87
SLUUBD3D – September 2015 – Revised September 2018
Copyright © 2015–2018, Texas Instruments Incorporated
Display Port
LEDCHG (Bit 2)
: Enables LED during charging. For LCD, the display is always active so this setting has
no effect.
1 = Activates display due to charging current
0 = Does not activate display due to charging current (default)
LEDRCA (Bit 1)
: Enables flashing of the LED display when the
[RCA]
flag in
BatteryStatus()
BatteryStatus is set.
1 = If the LED display is activated when
[RCA]
is set, the display flashes with
LED Flash
Period
.
0 = The LED display is not activated due to
[RCA]
being set. (default)
LEDR (Bit 0)
: Enables activation of the LED display on device-reset exit. For LCD, the display is
activated on device-reset exit; same as setting
LEDR
= 1.
1 = LED display is not activated on exit from device reset.
0 = LED display is activated (simulates a DISP transition) on exit from device reset (default).