0x4F StateOfHealth (SOH)
138
SLUUBD3D – September 2015 – Revised September 2018
Copyright © 2015–2018, Texas Instruments Incorporated
SBS Commands
17.44 0x4F StateOfHealth (SOH)
This command returns the state-of-health (SOH) information of the battery.
StateOfHealth()
is calculated
as a percentage of
FullChargeCapacity()
Design Capacity or Design Energy. It is a read-only command.
Byte 0: LSB of SOH in capacity
Byte 1: MSB of SOH in capacity
Byte 2: LSB of SOH in energy
Byte 3: MSB of SOH in energy
17.45 0x50 SafetyAlert
This command returns the
SafetyAlert()
flags. For a description of each bit flag, see the
ManufacturerAccess()
version of the same command in
SBS
Cmd
Name
Access
Protocol
Type
Min
Max
Default
Unit
Note
SE
US
FA
0x50
SafetyAlert()
—
R
R
Block
H4
0x00000
000
0xFFFF
FFFF
—
—
17.46 0x51 SafetyStatus
This command returns the
SafetyStatus()
flags. For a description of each bit flag, see the
ManufacturerAccess()
version of the same command in
SBS
Cmd
Name
Access
Protocol
Type
Min
Max
Default
Unit
Note
SE
US
FA
0x51
SafetyStatus()
—
R
R
Block
H4
0x00000
000
0xFFFF
FFFF
—
—
17.47 0x52 PFAlert
This command returns the
PFAlert()
flags. For a description of each bit flag, see the
ManufacturerAccess()
version of the same command in
SBS
Cmd
Name
Access
Protocol
Type
Min
Max
Default
Unit
Note
SE
US
FA
0x52
PFAlert()
—
R
R
Block
H4
0x00000
000
0xFFFF
FFFF
—
—
17.48 0x53 PFStatus
This command returns the
PFStatus()
flags. For a description of each bit flag, see the
ManufacturerAccess()
version of the same command in
SBS
Cmd
Name
Access
Protocol
Type
Min
Max
Default
Unit
Note
SE
US
FA
0x53
PFStatus()
—
R
R
Block
H4
0x00000
000
0xFFFF
FFFF
—
—
17.49 0x54 OperationStatus
This command returns the
OperationStatus()
flags. For a description of each bit flag, see the
ManufacturerAccess()