0x00 ManufacturerAccess() and 0x44 ManufacturerBlockAccess()
106
SLUUBD3D – September 2015 – Revised September 2018
Copyright © 2015–2018, Texas Instruments Incorporated
SBS Commands
1 = Detected
0 = Not Detected
UTD (Bit 11)
: Undertemperature During Discharge
1 = Detected
0 = Not Detected
UTC (Bit 10)
: Undertemperature During Charge
1 = Detected
0 = Not Detected
OTD (Bit 9)
: Overtemperature During Discharge
1 = Detected
0 = Not Detected
OTC (Bit 8)
: Overtemperature During Charge
1 = Detected
0 = Not Detected
ASCDL (Bit 7)
: Short Circuit During Discharge Latch
1 = Detected
0 = Not Detected
ASCD (Bit 6)
: Short Circuit During Discharge
1 = Detected
0 = Not Detected
AOLDL (Bit 5)
: Overload During Discharge Latch
1 = Detected
0 = Not Detected
AOLD (Bit 4)
: Overload During Discharge
1 = Detected
0 = Not Detected
OCD (Bit 3)
: Overcurrent During Discharge
1 = Detected
0 = Not Detected
OCC (Bit 2)
: Overcurrent During Charge
1 = Detected
0 = Not Detected
COV (Bit 1)
: Cell Overvoltage
1 = Detected
0 = Not Detected
CUV (Bit 0)
: Cell Undervoltage
1 = Detected
0 = Not Detected
17.2.35 ManufacturerAccess() 0x0051 SafetyStatus
This command returns the
SafetyStatus()
flags on
ManufacturerBlockAccess()
or
ManufacturerData()
.