0x00 ManufacturerAccess() and 0x44 ManufacturerBlockAccess()
108
SLUUBD3D – September 2015 – Revised September 2018
Copyright © 2015–2018, Texas Instruments Incorporated
SBS Commands
ASCDL (Bit 7)
: Short Circuit During Discharge Latch
1 = Detected
0 = Not Detected
ASCD (Bit 6)
: Short Circuit During Discharge
1 = Detected
0 = Not Detected
AOLDL (Bit 5)
: Overload During Discharge Latch
1 = Detected
0 = Not Detected
AOLD (Bit 4)
: Overload During Discharge
1 = Detected
0 = Not Detected
OCD (Bit 3)
: Overcurrent During Discharge
1 = Detected
0 = Not Detected
OCC (Bit 2)
: Overcurrent During Charge
1 = Detected
0 = Not Detected
COV (Bit 1)
: Cell Overvoltage
1 = Detected
0 = Not Detected
CUV (Bit 0)
: Cell Undervoltage
1 = Detected
0 = Not Detected
17.2.36 ManufacturerAccess() 0x0052 PFAlert
This command returns the
PFAlert()
flags on
ManufacturerBlockAccess()
or
ManufacturerData()
.
Status
Condition
Action
Activate
0x0052 to
ManufacturerAccess()
Outputs
PFAlert()
flags on
ManufacturerBlockAccess()
or
ManufacturerData()
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
SOTF
TS3
TS2
TS1
AFE_
XRDY
AFE_
OVRD
AFEC
AFER
DFETF
CFETF
VIMR
SOT
SOCD
SOCC
SOV
SUV
SOTF (Bit 15)
: Safety Overtemperature FET Failure
1 = Detected
0 = Not Detected
TS3 (Bit 14)
: Open Thermistor – TS3 Failure
1 = Detected
0 = Not Detected
TS2 (Bit 13)
: Open Thermistor – TS2 Failure
1 = Detected