0x11 RunTimeToEmpty()
128
SLUUBD3D – September 2015 – Revised September 2018
Copyright © 2015–2018, Texas Instruments Incorporated
SBS Commands
NOTE:
If
BatteryMode()[CAPM]
= 0, then the data reports in mAh.
If
BatteryMode()[CAPM]
= 1, then the data reports in 10 mWh.
17.19 0x11 RunTimeToEmpty()
This read-word function returns the predicted remaining battery capacity based on the present rate of
discharge.
SBS
Cmd
Name
Access
Proto-
col
Type
Min
Max
Unit
SE
US
FA
0x11
RunTimeToEmpty()
R
R
R
Word
U2
0
65535
min
NOTE:
65535 = Battery is not being discharged.
17.20 0x12 AverageTimeToEmpty()
This read-word function returns the predicted remaining battery capacity based on
AverageCurrent()
.
SBS
Cmd
Name
Access
Proto-
col
Type
Min
Max
Unit
SE
US
FA
0x12
AverageTimeToEmpty()
R
R
R
Word
U2
0
65535
min
NOTE:
65535 = Battery is not being discharged.
17.21 0x13 AverageTimeToFull()
This read-word function returns the predicted time to full charge based on
AverageCurrent()
.
SBS
Cmd
Name
Access
Proto-
col
Type
Min
Max
Unit
SE
US
FA
0x13
AverageTimeToFull()
R
R
R
Word
U2
0
65535
min
NOTE:
65535 = Battery is not being discharged.
17.22 0x14 ChargingCurrent()
This read-word function returns the desired charging current.
SBS
Cmd
Name
Access
Proto-
col
Type
Min
Max
Unit
SE
US
FA
0x14
ChargingCurrent()
R
R
R
Word
U2
0
65535
mA
NOTE:
65535 = Request maximum current
Scaled per
SpecificationInfo()
17.23 0x15 ChargingVoltage()
This read-word function returns the desired charging voltage.