Safety Cell Overvoltage Permanent Fail
37
SLUUBD3D – September 2015 – Revised September 2018
Copyright © 2015–2018, Texas Instruments Incorporated
Permanent Fail
Class
Subclass
Name
Type
Min
Max
Default
Unit
Permanent Fail
AFE SUV
Threshold
I2
1580
3100
1750
mV
Permanent Fail
AFE SOV/AFE SUV
SOV and SUV Delay
U1
0
255
2
s
This register is representative of the bq769x0 PROTECT 3 register.
Class
Subclass
Name
Format
Size in
Bytes
Min
Max
Default
Unit
Settings
AFE SOV/AFE
SUV
SOV and SUV
Delay
Hex
1
0x00
0xF0
0x50
—
7
6
5
4
3
2
1
0
SUV_D1
SUV_D0
SOV_D1
SOV_D0
RSVD
RSVD
RSVD
RSVD
LEGEND: R/W = Read/Write; R = Read only; -
n
= value after reset
SUV_D1:0 (Bits 7–6)
: Safety Undervoltage Delay Time
00 = 1 s
01 = 4 s
10 = 8 s
11 = 16 s
SOV_D1:0 (Bits 5–4)
: Safety Overvoltage Delay Time
00 = 1 s
01 = 2 s
10 = 4 s
11 = 8 s
RSVD: (Bits 3–0)
: Reserved
4.5
Safety Cell Overvoltage Permanent Fail
The bq78350-R1 uses the OV Protection function of the companion AFE for this feature and can be
configured to permanently disable the battery in the case of severe overvoltage in any of the cells. This
feature cannot be disabled.
The voltage threshold setting is set in
AFE SOV:Threshold
, which the device will map to the available
settings in the companion AFE with the maximum setting of 4703 mV and the minimum of 3140 mV.
The delay timing configuration for this feature is combined in the same register with the delay time of the
Safety Undervoltage feature.
Status
Condition
Action
Normal
AFEStatus() [OV]
= 0
PFStatus()[SOV]
= 0
Trip
AFEStatus() [OV]
= 1
PFStatus()[SOV]
= 1
BatteryStatus()[TDA]
= 1
BatteryStatus()[TCA]
= 1
Class
Subclass
Name
Type
Min
Max
Default
Unit
Permanent Fail
AFE SOV
Threshold
I2
3150
4700
4350
mV
4.6
Safety Overcurrent in Charge Permanent Fail
The device can permanently disable the battery in the case of a severe OVERCURRENT IN CHARGE
state.