0x4C DynamicPower()
137
SLUUBD3D – September 2015 – Revised September 2018
Copyright © 2015–2018, Texas Instruments Incorporated
SBS Commands
SBS Cmd
Mode
Name
Format
Size in Bytes
Min
Max
Default
Unit
0x30
R
Reserved
Unsigned
Integer
2
0
65535
—
mV
0x31
CellVoltage15
0x32
CellVoltage14
0x33
CellVoltage13
0x34
CellVoltage12
0x35
CellVoltage11
0x36
CellVoltage10
0x37
CellVoltage9
0x38
CellVoltage8
0x39
CellVoltage7
0x3A
CellVoltage6
0x3B
CellVoltage5
0x3C
CellVoltage4
0x3D
CellVoltage3
0x3E
CellVoltage2
0x3F
CellVoltage1
17.41 0x4C DynamicPower()
The bq78350-R1 includes the read-only
DynamicPower()
word command, which returns a value of
Current()
×
Voltage()
in 10 mW units. If
Current()
and/or
Voltage()
are scaled, then the units of
DynamicPower()
are also scaled.
SBS Cmd
Mode
Name
Format
Size in
Bytes
Min
Max
Default
Unit
0x4C
R
Dynamic
Power
Integer
2
–32768
32767
—
10 mW
17.42 0x4D ExtAveCellVoltage()
This read-word function returns the external average cell voltage measurement, if enabled, which can be
used within the gas gauging algorithm for EDV2, EDV1, and EDV0 detection.
SBS Cmd
Mode
Name
Format
Size in
Bytes
Min
Max
Default
Unit
0x4D
R
ExtAveCell
Voltage
Unsigned
Integer
2
0
65535
—
mV
17.43 0x4E PendingEDV()
This read-word function returns the predicted EDV2 until EDV2 is reached, then the predicted EDV1 until
EDV1 is reached, and then the predicted EDV0. The format is Little Endian.
SBS Cmd
Mode
Name
Format
Size in
Bytes
Min
Max
Default
Unit
0x4E
R
PendingEDV
Unsigned
Integer
2
0
65535
—
mV