0x0D RelativeStateOfCharge()
127
SLUUBD3D – September 2015 – Revised September 2018
Copyright © 2015–2018, Texas Instruments Incorporated
SBS Commands
Status Condition
Action
Each
CycleCount()
increment after last valid FCC update
MaxError()
increment by 0.25% to a maximum of
100%
After
Requested Learning Cycle Count
increments of
CycleCount()
since
the last FCC update
CEDV GaugingStatus() [CF]
= 1
Class
Subclass
Name
Type
Min
Max
Default
Unit
Fuel Gauging
CEDV Cfg
Requested Learning Cycle
Count
U1
1
255
20
Cycles
17.15 0x0D RelativeStateOfCharge()
This read-word function returns the predicted remaining battery capacity as a percentage of
FullChargeCapacity()
and is an output of the CEDV gas gauging feature.
SBS
Cmd
Name
Access
Proto-
col
Type
Min
Max
SE
US
FA
0x0D
RelativeStateOfCharge()
R
Word
U1
0%
100%
17.16 0x0E AbsoluteStateOfCharge()
This read-word function returns the predicted remaining battery capacity as a percentage of
Design
Capacity
, and is an output of the CEDV gas gauging feature.
SBS
Cmd
Name
Access
Proto-
col
Type
Min
Max
SE
US
FA
0x0E
AbsoluteStateOfCharge()
R
Word
U1
0%
100%
17.17 0x0F RemainingCapacity()
This read-word function returns the predicted remaining battery capacity and is an output of the CEDV gas
gauging feature. It is scaled per
SpecificationInfo()
.
SBS
Cmd
Name
Access
Proto-
col
Type
Min
Max
Unit
SE
US
FA
0x0F
RemainingCapacity()
R
R
R
Word
U2
0
65535
mAh
10 mWh
NOTE:
If
BatteryMode()[CAPM]
= 0, then the data reports in mAh.
If
BatteryMode()[CAPM]
= 1, then the data reports in 10 mWh.
17.18 0x10 FullChargeCapacity()
This read-word function returns the predicted battery capacity when fully charged and scaled per
SpecificationInfo()
.
SBS
Cmd
Name
Access
Proto-
col
Type
Min
Max
Unit
SE
US
FA
0x10
FullChargeCapacity()
R
R
R
Word
U2
0
65535
mAh
10 mWh