Störungen,Ur-
sachen, Behebung
Faults, causes,
remedies
Storingen, oorzaa-
ken en remedie
Fel, Orsak,
Åtgärd
Défaillances, cau-
ses et dépannage
Disturbi: cause e
rimedi
15
- Key operated switch in
the bottom control on “I”
- switch to “0”
- Bracing not possible
- Key operated switch for
operating console in
wrong position
- select correct positi-
on
- Pivot telescope is not in
the transport position
- lower completely
until transport switch
is activated
- Lowering upper arm
and raising lower arm
not possible
- load interruption acti-
vated
- Raise load interrup-
tion by raising upper
arm or lowering under
arm deactivate
-green lamp blinking
- Bracing monitor not
isolated since it was not
braced high enough
- inspect
- brace higher
-red lamp remains on
- System error
- ring service
- no function whatsoever
at power supply via
construction site feed
point or drive motor
-Safety elements have
triggered (fuses, FI pro-
tection)
- check safety ele-
ments and switch on
-Defective extension
cord
- check and replace if
necessary
- wrong cable diameter
for too long extension
cord
- select correct cable
diameter
- Emergency stop acti-
vated
- deactivate