TEMA TELECOMUNICAZIONI SRL
T11-T12 Multifunction Automated Attendant
MAS-T11-T12-rev03-EN
Pagina 35 di 38
Field
number
Parameter name
Alarm telephone dialer – Operational mode switching
Default
Maximum
field length
56 #
Number to call for
alarm 1
Insert number to call in case of event associated to alarm 1.
Empty 1
57 #
Number to call for
alarm 2
Insert number to call in case of event associated to alarm 2, or # to intend it for
switching between modes.
Empty 1
35 #
Gap between
attempts
Indicates the interval between two consecutive attempts
0300 4
36 #
Number of attempts
Indicates how many attempts to be made before taking the user as not
reachable and stop trying.
10 2
Field
number
Parameter name
Signalling for matching towards PBX
Default
Maximum
field length
14 #
On hold flash
duration
In milliseconds. Indicates flash parameter time duration required from PBX in
order to set an incoming call in stand-by mode.
100 4
15 #
Return flash
duration
In milliseconds. Indicates flash parameter time duration required from PBX in
order to retrieve an incoming call from stand-by mode.
100 4
18 #
Digits sending
delay
In milliseconds. Delay tIme between flash start and sending of the next set of
selection digits.
1000 4
16 #
Digits after on hold
by flash
For PBX which need further digits to put in stand by mode
Empty 3
17 #
Digits after return
flash
For PBX which need further digits to retrieve from stand by mode
Empty 3
Field
number
Parameter name
Busy + release tone detection mask
Default
Maximum
field length
10 #
Minimum tone
length
In milliseconds. Indicates minimum time length of the single tone in the PBX
busy tone.
80 4
9 #
Maximum tone
length
In milliseconds. Indicates maximum time length of the single tone in the PBX
busy tone.
600 4
12 #
Minimum pause
length
In milliseconds. Indicates minimum time length of the silence between single
tones in the PBX busy tone..
80 4
11 #
Maximum pause
length
In milliseconds. Indicates maximum time length of the silence between single
tones in the PBX busy tone.
600 4
13 #
Number of
computations
Indicates the amount of tone sequences in order to validate the presence of a
busy/release tone.
5 2
Field
number
Parameter name
Selection digits mask
Default
Maximum
field length
25 #
DTMF digit length
Duration of digit, in milliseconds.
100
4
26 #
DTMF digit pause
length
Duration of pause between digits, in milliseconds.
100 4
38 #
Urban lines
engagement
If call divertion service is used, this code must be used by the system in order to
engage line.
Empty 3
Field
number
Parameter name
Service passwords
Default
Maximum
field length
19 #
Programming
password
The password to insert in order to enter the main programming service. If the
parameter is left blank, system will consider the default value.
3333 6
20 #
Service password
Calling the system: the password to enter in order to retrieve messages and/or
switch operational mode.
4444 6
21 #
Remote control pwd
(ab./disab. relay)
This password allows to activate or deactivate the contact relay for the remote
control service.
5555 6
22 #
Telephone dialer
password (alarms)
Calling the system: the password to enter in order to retrieve alarm status.
After a notification call: the password can be used to acquaint alarm notification
and remotely cancel alarms.
6666 6
23 #
Least Cost
Rounting password
Calling the system: the password to enter in order to make phone calls with
local charges.
7777 6
Field
number
Parameter name
General parameters
Default
Maximum
field length
27 #
Operational mode
Indicates current operational mode.
1
1
28 #
Message memory
partition
Configure message memory, allows setting of message / length
0
1
8 #
Message system
main language
Set main language for system messages
1
1
32 #
Messages pause
In milliseconds. Indicates lenght of interval between message repetitions.
5000
4
34 #
Remote control
relay
Configure relay activation mode.
0
1
40 #
Serial number
Read only device identification code.
---
8
37 #
Automated
attendant
Automated attendant service.
1
1
47 #
PBX numeration
plane
Indicates the number of extension digits in the numerative plane.
3 1
24 #
SEL lever
Future expansion
0
1
99 #
FAX number
Fax number for Fax switch function.
(only for T11 systems)
Empty
3