9.6.2 Busy / Release Tone Mask Parameters Programming
Parameter
number
Parameter
name
Description
Default
value
Parameter
max. length
Your settings
10 #
Minimum tone
duration
In milliseconds. Indicates minimum time
length of the single tone in the PBX busy
tone.
Range : from 30 to 600
80 4
#
9 #
Maximum
tone duration
In milliseconds. Indicates maximum time
length of the single tone in the PBX busy
tone.
Range : from 30 to 600
600 4
#
12 #
Minimum
pause
duration
In milliseconds. Indicates minimum time
length of the silence between single tones in
the PBX busy tone.
Range : from 30 to 600
80 4
#
11 #
Maximum
pause
duration
In milliseconds. Indicates maximum time
length of the silence between single tones in
the PBX busy tone.
Range : from 30 to 600
600 4
#
13 #
Number of
count
Indicates the amount of tone sequences in
order to validate the presence of a
busy/release tone.
Range : from 3 to 15
5 2
#
Note
¾
CAUTION:
the busy and release tones have to be defined only through this mask. The
former is used to understand if the extension is busy while the system tries to divert an
incoming call, the latter is used to release the line if the caller hangs up. It is recommended to
use the default values or modify them only if line tones are different from the standard ones.
9.6.3 Selection Parameters Programming
Parameter
number
Parameter
name
Description
Default
value
Parameter
max. Lenght
Your settings
25 #
DTMF digit
duration
Duration of digit, in milliseconds.
Range : from 35 to 200
100 4
#
26 #
DTMF digit
pause
duration
Duration of pause between digits, in
milliseconds.
Range : from 35 to 200
100 4
#
38 #
External line
PBX prefix
If call divertion service is used, this code
must be used by the system in order to
engage the line.
Range : max 3 digits DTMF
Empty 3
#
Note
¾
CAUTION:
it is recommended to use the default values in parameter 25 and 26.