General Parameters Programming
Parameter
number
Parameter name
Description
Default
value
Parameter
max. length
Your
settings
27 #
Operational
mode
Indicates current operational mode.
Options available are the following 4:
1 = Day
mode 1 (M1)
2 = Night
mode 2 (M2)
3 = Festivity mode 3 (M3)
4 = Holiday mode 4 (M4)
Range : from 1 to 4
1 1
#
28 #
Message
memory partition
Day-Night-Fest.-
Holidays
(M1-M2-M3-M4)
Times in seconds
CAUTION,
see note in
par. 10.1
Configure message memory, allows setting of
message / length. 8 options as following:
Ans. Mach. enabled / disabled
Value M1-M2-M3-M4 / M1-M2-M3-M4
•
0 = 20-40-30-30 / 60-120-90-90
•
1 = 30-30-30-30
/ 90-90-90-90
•
2 = 30-50-40-no
/ 90-150-120-no
•
3 = 40-80-no-no
/ 120-240-no-no
•
4 = 80-40-no-no
/ 240-120-no-no
•
5 = 120-no-no-no
/ 360-no-no-no
•
6 = no-120-no-no
/ no-360-no-no
•
7 = 60-60-no-no
/ 180-180-no-no
Range : from 0 to 7
0 1
#
8 #
Message system
main language
Set main language for system messages:
•
0 = Italian only
•
1 = English only
•
2 = bilingual I English
Range : from 0 to 2
1 1
#
32 #
Messages pause In milliseconds. Indicates lenght of interval
between message repetitions.
Range : from 100 to 9999
5000 4
#
34 #
Remote control
relay
Configure relay activation mode. Options are the
following:
•
0 = contact on, with memory
•
1 = contact on, without memory
•
2 = 2 seconds pulse, then off
•
3 = sequence 1/1sec on/off with memory
•
4 = sequence 1/1sec on/off without memory
•
5 = sequence 2s/1min with memory
•
6 = sequence 2s/1min without memory
Range : from 0 to 6
0 1
#
40 #
Serial number
Read only device identification code.
Range : max 8 digits
--- 8
#
37 #
Automated
attendant
Automated attendant service. May be disabled in
order to activate the transfer only at the end of
the message (if enabled).See parameter 51, 52,
53, 54.
•
0 = Automated attendant disabled
•
1 = Automated attendant enabled
Range : from 0 to 1
1 1
#
47 #
PBX numeration
plane
Indicates the number of extension digits in the
numerative plane, in order to speed up dialed
digit acquisition
Range : from 2 to 5
3 1
#
24 #
SEL function
Future expansion
•
0 = no function, leave 0
Range : from 0 to 9
0 1
#
99 #
FAX number
(only for T11
systems)
Fax number for Fax switch function.
•
empty = disabled
•
(number) = number to call
Range : max 3 digits
Empty 3
#