Teledyne LeCroy
Projects
82
Sierra M6
‐
2 SAS/SATA Protocol Analyzer User Manual
Snapshot Mode
To trigger immediately on any pattern, check the
Don’t
care
(Snapshot)
button.
Figure 2.63: Default Trigger Selected
Manual Trigger Mode
To perform a manual trigger, check the
Manual Trig
radio
button. In the
Manual
Trigger
mode, the analyzer captures bus traffic continually from when you use the Manual
Trigger until you click the
Stop
Recording
button (on the analyzer toolbar), which triggers
the analyzer. Clicking the
Manual
Trigger
button on the application toolbar creates a
Trigger Event and uploads the trace with the specified trigger position.
Any Trigger in Pattern Mode
In
Pattern
mode, the Analyzer triggers whenever any of the patterns selected for
triggering occurs (an OR condition). The procedure for selecting trigger parameters is
identical to that for selecting capture parameters. All items selected for triggering appear
in the Project Tree.
To define patterns for triggering, check the
Pattern
button in the Trigger dialog (see
).