2 SAS/SATA Protocol Analyzer User Manual
411
Creating Global Rules
Teledyne LeCroy
Figure 4.39: Example 6: Entering the Second Event
The Event Properties dialog box appears.
4. In the Type column on the left, choose
Timer
. Set the timer for random timing with a
maximum time limit of 1.790 seconds.
5. Click
OK
to close the Event Properties dialog box.
6. Click the prompt to
add
an
action
to correspond with the second event.
Figure 4.40: Example 6: Entering Second Action
The Action Properties dialog box appears.
7. In the Type list on the left, choose
Stop
Scenario
as the action that you want after
the timer has expired.
8. Click
OK
to close the Action Properties dialog box.