Sierra M6
‐
2 SAS/SATA Protocol Analyzer User Manual
409
Creating Global Rules
Teledyne LeCroy
4.9.5
Example 5: Multiple Actions on a Single Event
In this example, an event triggers a set of actions. The actions occur at the same time. The
device waits for an ACK from the initiator. When it occurs, the device beeps, injects an RD
error, and increments a counter monitoring for that event (ACK from initiator).
1. Click the
New
Scenario
button in the main library or one of the device libraries. In
the Scenario Properties dialog, enter the scenario name, description, and direction
of traffic change.
2. As in previous examples, configure the first event and its response in the Global
Rules area. Choose
ACK
primitive as the event and
Beep
as the action. From the
Action Properties drop
‐
down menu, enter
500
ms
as the duration of the beep.
3. Click the
add
another
action
prompt to add a second action.
Figure 4.37: Example 5: Entering the Second Action
The Action Properties dialog box appears.
4. Choose
Inject
RD
Error
as the second action.
5. Click the
add
another
action
prompt to add a third action.
The Action Properties dialog box appears.
6. Choose
Monitor/Count
as the third action.
7. Click
OK
to close the Action Properties dialog box.
Содержание Sierra M6-2
Страница 37: ...Sierra M6 2 SAS SATA Protocol Analyzer User Manual 35 Expandability Teledyne LeCroy ...
Страница 375: ...Sierra M6 2 SAS SATA Protocol Analyzer User Manual 373 Interface Teledyne LeCroy ...
Страница 436: ...Teledyne LeCroy Scenario Batch Files 434 Sierra M6 2 SAS SATA Protocol Analyzer User Manual ...
Страница 526: ...Teledyne LeCroy 524 Sierra M6 2 SAS SATA Protocol Analyzer User Manual ...