Teledyne LeCroy
Sierra Trainer Generation Language
460
Sierra M6
‐
2 SAS/SATA Protocol Analyzer User Manual
# RawData with variables embedded
RawData {
K28.5 D24.0 D30.0 D01.4
@variableName1
50 00 62 B0
00 00 00 30
50 08 05 EF
$C
00 00 00 01
00 00 00 00
SendCRC
K28.5 D24.0 D07.3 D31.4 }
}
When there are variable values in RawData, you must include SendCRC command instead
of last dword. Otherwise, wrong CRC value will be sent. The constraints are:
Variables are not allowed on First and LAST DWORD (instead of start/end
frames).
SendCRC is only supported on last DWORD before end of frame.
Raw 10 bits codes. This definition might cause running disparity errors.
Sending OpenAddressFrame Using
Standard Frame Templates
Sending the Same
OpenAddressFrame Using Raw Data
Mechanism
SendOpenAddressFrameSTP {
SourceAddress = { 500805EF FFFF0041 }
DestinationAddress = { 500062B0 00000030
}
ArbitrationWaitTime = 0x1
AccessZoneManagement= 0x0
SourceZoneGroup = 0x0
ConnectionRate = 0x8
Features = 0x0
InitiatorConnectionTag = 0x1
InitiatorPort = 0x0
MoreCompatibleFeatures = 0x0
PathwayBlockedCount = 0x0
# CRC = 0x050F19E0 # good crc }
Set ScramblingMode =
SCRAMBLING_MODE_SAS
RawData {
K28.5 D24.0 D30.0 D01.4
21 08 00 01
50 00 62 B0
00 00 00 30
50 08 05 EF
FF FF 00 41
00 00 00 01
00 00 00 00
05 0F 19 E0
K28.5 D24.0 D07.3 D31.4 }
* CRC is inserted manually
Содержание Sierra M6-2
Страница 37: ...Sierra M6 2 SAS SATA Protocol Analyzer User Manual 35 Expandability Teledyne LeCroy ...
Страница 375: ...Sierra M6 2 SAS SATA Protocol Analyzer User Manual 373 Interface Teledyne LeCroy ...
Страница 436: ...Teledyne LeCroy Scenario Batch Files 434 Sierra M6 2 SAS SATA Protocol Analyzer User Manual ...
Страница 526: ...Teledyne LeCroy 524 Sierra M6 2 SAS SATA Protocol Analyzer User Manual ...