COMINIT
Settings
COMINIT_NegLen
800
The number of bursts to send as part of this OOB
type.Each Burst is followed by an Idle. The Burst
‐
Idle
pairs are repeated the requested number of times,
and then followed by the Negation_length of Idle.
COMINIT_IdleLen
480
Burst time between each OOB idle in OOBIs.During
the specified period, the generator will send
ALIGN(0) at the specified speed.
COMINIT_BurstLen
160
Idle time between each OOB burst in OOBIs.During
the specified period, the generator will keep the line
at electric idle.
COMINIT_NumBursts
6
Negation time at the end of the OOB signal in
OOBIs.During the specified period, the generator will
keep the line at electric idle.
COMWAKE
Settings
COMWAKE_NegLen
280
The number of bursts to send as part of this OOB
type.Each Burst is followed by an Idle. The Burst
‐
Idle
pairs are repeated the requested number of times,
and then followed by the Negation_length of Idle.
COMWAKE_IdleLen
160
Burst time between each OOB idle in OOBIs.During
the specified period, the generator will send
ALIGN(0) at the specified speed.
COMWAKE_BurstLen
160
Idle time between each OOB burst in OOBIs.During
the specified period, the generator will keep the line
at electric idle.
COMWAKE_NumBursts
6
Negation time at the end of the OOB signal in
OOBIs.During the specified period, the generator will
keep the line at electric idle.
COMSAS Settings
COMSAS_NegLen
2400
The number of bursts to send as part of this OOB
type.Each Burst is followed by an Idle. The Burst
‐
Idle
pairs are repeated the requested number of times,
and then followed by the Negation_length of Idle.
COMSAS_IdleLen
1440
Burst time between each OOB idle in OOBIs.During
the specified period, the generator will send
ALIGN(0) at the specified speed.
COMSAS_BurstLen
160
Idle time between each OOB burst in OOBIs.During
the specified period, the generator will keep the line
at electric idle.
COMSAS_NumBursts
6
Negation time at the end of the OOB signal in
OOBIs.During the specified period, the generator will
keep the line at electric idle.
Setting
Default
Value
Description
Содержание Sierra M6-2
Страница 37: ...Sierra M6 2 SAS SATA Protocol Analyzer User Manual 35 Expandability Teledyne LeCroy ...
Страница 375: ...Sierra M6 2 SAS SATA Protocol Analyzer User Manual 373 Interface Teledyne LeCroy ...
Страница 436: ...Teledyne LeCroy Scenario Batch Files 434 Sierra M6 2 SAS SATA Protocol Analyzer User Manual ...
Страница 526: ...Teledyne LeCroy 524 Sierra M6 2 SAS SATA Protocol Analyzer User Manual ...