ADFM® Flow Meter
Section 2 Setup and Installation
2-42
Figure 2-44 Early HTI: Component measurements and sensor positioning
I
D
Pipe wall
Se
nsor tip
(t
ypic
al inser
tion depth
S = 1/4”
to 1/2”)
7-11
1-5
S
E
C
V
T
P
Pipe W
all
Sensor
Nipple
Valve
Saddle Tap
E
L
2.25”
L
Sensor length (printed on box; standard 28" nom.)
P
Pipe wall thickness
E
Extended length (L + 2.25")
C
Minimum clearance for sensor removal
(E + V + T)
V
Valve (user-supplied)
D
Distance from top of valve to inner wall
(V + T + P)
T
Tapping saddle, thread-o-let, or spool piece
(user-supplied)
I
Insertion depth (L - (S+P))
S
Sensor tip insertion depth (
1
/
4
" to
1
/
2
")
Measured
sensor length
(L)
Содержание ADFM Hot Tap