Table 1-2 Technical Specifications: Pro20 Open Channel Velocity Sensor
Sensor Body
Operating Temperature
23 to 95 °F (-5 to 35 °C)
Housing Material
Urethane
Static Pressure
250 psi nominal
Dimensions
8 x 3 x 1.5 inches (200 x 75 x 40 mm)
Weight
3.2 lbs (1.5 kg)
Beam Angles
1 & 3: 10°front-back; 20°to side
2 & 4: 20° front-back; 30° to side
Sensor Signal Cable
Operating Temperature
-40 to 125 °F (-40 to 52 °C)
Material
Polyethyline jacket
Length
50 ft (15 m) std.
100 ft (30 m) and 150 ft. (45 m) optional lengths available
Minimum Bend Radius
6 in (150 mm)
Outer Diameter
0.5 in (13 mm) nominal
Table 1-3 Technical Specifications: Hot Tap Insertion Velocity Sensor
Sensor Body
Operating Temperature
23 to 95 °F (-5 to 35 °C)
Housing
Plastic transducer assembly
on corrosion resistant stainless steel stem.
Rated NEMA 6P, IP68, defined as validated for submersion to 20 feet of depth
for 48 hours.
Static Pressure
200 psi nominal
a
Dimensions:
Sensor Head Diameter
Std stem length
b
Insertion
1.375 in. (35 mm)
2 feet (610 mm)
Fits 2 inch NPT (50 mm) standard tap
Weight (includes 50 ft. cable)
15 lbs (6.8 kg)
Beam Angles
1 & 3: 10°front-back; 20° to side
2 & 4: 20° front-back; 30° to side
Sensor Signal Cable
Operating Temperature
-40 to 140 °F (-40 to 60 °C)
Material
Polyethylene jacket
Length
50 ft (15 m) std; 100 ft (30 m) optional
c
Minimum Bend Radius
6 in (150 mm)
Outer Diameter
0.5 in (13 mm) nominal
a.
Use safety installation kit (60-7007-030) for pressures above 100psi. Applications with pressures between 200 and 300
psi require a schedule 80 nipple (contact factory).
b.
Custom stem lengths are available; call factory for more information.
c.
Custom cable lengths are available; call factory for more information.
Содержание ADFM Hot Tap
Страница 2: ......
Страница 4: ......
Страница 20: ...ADFM Flow Meter Section 1 Introduction 1 10 ...
Страница 85: ...ADFM Flow Meter Section 2 Setup and Installation 2 65 Figure 2 73 Viewing data in Expert View ...
Страница 86: ...ADFM Flow Meter Section 2 Setup and Installation 2 66 ...
Страница 98: ...ADFM Flow Meter Section 3 Maintenance and Troubleshooting 3 12 ...
Страница 114: ......
Страница 116: ......