
ADFM® Flow Meter
Section 2 Setup and Installation
2-35
Figure 2-36 Installation example
2.6.7 Applications With
Permanent Silt
For pipes or channels where sediment or debris will be present,
Teledyne Isco offers mounting accessories for elevating the
sensor.
The debris fairing attaches directly to the mounting plate or ring,
and the sensor is mounted in the top of the fairing for a lift of 3
inches. Fairing spacers add 1, 2, and 4 inches each, and may be
combined for additional lift.
The sensor, fairing, and spacer(s) are attached to the mounting
plate with three threaded couplers and mounting screws.
Cable in this area
MUST be secured and protected.
Cable Conduit
(min. 2” dia.)
Align sensor(s) parallel
w/ the channel walls and
flat on the channel bottom.
Minimum bend
radius 6”
Sensor mounting
plate
Содержание ADFM Hot Tap
Страница 2: ......
Страница 4: ......
Страница 20: ...ADFM Flow Meter Section 1 Introduction 1 10 ...
Страница 85: ...ADFM Flow Meter Section 2 Setup and Installation 2 65 Figure 2 73 Viewing data in Expert View ...
Страница 86: ...ADFM Flow Meter Section 2 Setup and Installation 2 66 ...
Страница 98: ...ADFM Flow Meter Section 3 Maintenance and Troubleshooting 3 12 ...
Страница 114: ......
Страница 116: ......