![Tektronix LTA7P Series Скачать руководство пользователя страница 41](http://html1.mh-extra.com/html/tektronix/lta7p-series/lta7p-series_service-manual_1078035041.webp)
Operating Information
TLA7Nx, TLA7Px, & TLA7Qx Logic Analyzer Module Service Manual
2- 9
The logic analyzer module may require several minutes to run the self calibration
depending on the number of channels. Select the Calibration and Diagnostics
property sheet from the System menu. Select the Self Calibration tab page and
select the logic analyzer module. Click the Run button to start the self calibra-
tion. Upon completing the self calibration, the logic analyzer module menu
selection changes from Running to Calibrated.
Menu Overview
The logic analyzer is controlled by interactive windows through
the TLA application. The TLA application consists of the following windows:
H
System Window. This window provides an overview of the entire logic
analyzer. Use this window to navigate through the logic analyzer.
The center of the System window displays icons that represent hardware
modules installed in the logic analyzer. The icons are linked to the other
windows in the logic analyzer.
H
Setup Window. A setup window exists for each module in the logic analyzer.
It contains all of the setup information for the logic analyzer module such as
clocking, memory depth, threshold information, and channel information.
Menus and dialogs contain information to set up the window as needed.
For the DSO, the Setup window contains setup information for each DSO
channel such as the input voltage ranges, bandwidth, coupling, and
termination. It also contains horizontal setup information and a link to the
DSO Trigger window.
H
Trigger Window. The Trigger window provides access to the logic analyzer
module or DSO module trigger setups. For either module, you can specify
various trigger events and trigger actions to help you capture the data that
you are interested in.
H
Listing Data Window. The Listing Data window displays acquired data as
tabular text. Each column of data represents one group of data or other
logical data information, such as time stamps. Each row of data represents a
different time that the data was acquired; newer samples of data display
below older samples.
H
Waveform Data Window. The Waveform Data window displays acquired
data as graphical waveforms. All defined channel groups display as busforms
for the logic analyzer and as individual analog channels for the DSO module.
H
On/Off Buttons. These buttons enable or disable the operation of the
modules. Click the appropriate button to enable or disable the modules.
Refer to the online help for more information on the individual menus, icons,
and fields within each window. You may also want to refer to the
Tektronix Logic
Analyzer Family User Manual
for additional information.
Содержание LTA7P Series
Страница 4: ......
Страница 14: ...Service Safety Summary x TLA7Nx TLA7Px TLA7Qx Logic Analyzer Module Service Manual...
Страница 22: ...Introduction xviii TLA7Nx TLA7Px TLA7Qx Logic Analyzer Module Service Manual...
Страница 86: ......
Страница 96: ...Logic Analyzer Module Adjustment Procedures 5 10 TLA7Nx TLA7Px TLA7Qx Logic Analyzer Module Service Manual...
Страница 148: ...Troubleshooting 6 40 TLA7Nx TLA7Px TLA7Qx Logic Analyzer Module Service Manual...
Страница 154: ...Electrical Parts List 8 2 TLA7Nx TLA7Px TLA7Qx Logic Analyzer Module Service Manual...
Страница 170: ...Mechanical Parts List 10 14 TLA7Nx TLA7Px TLA7Qx Logic Analyzer Module Service Manual...
Страница 171: ......
Страница 172: ......