Adjustment/Verification Fixture Adjustment
TLA7Nx, TLA7Px, & TLA7Qx Logic Analyzer Module Service Manual
5- 15
The following procedure adjusts the data pulse width.
Parameter tested
Data Pulse Width
Equipment
Required
Adjustment/verification fixture and power supply (item 2)
Oscilloscope (item 3)
Two 1 M
Ω
10X oscilloscope probe (item 4)
Shorting jumpers (item 14)
Prerequisites
Warm-up time: 30 minutes for adjustment/verification fixture and test
equipment
1.
Set up the oscilloscope by pressing Setup, and then press Factory Setup, and
then press OK Confirm Factory Init to return the oscilloscope to default
conditions.
2.
Set up the oscilloscope as listed below.
a.
Set up the CH1 Vertical menu as follows:
H
Coupling
DC/50
Ω
H
Fine Scale
200 mV/div
H
Position
--3.32 div
b.
Set up the Horizontal menu as follows:
H
Time Base
Main
H
Record Length
5000
H
Horizontal Scale
Main Scale @ 1 ns/div
c.
Set up the Trigger menu as follows:
H
Source
CH1
H
Coupling
DC
H
Slope
+
H
Level
700 mV
H
Mode
Normal
d.
Set up the Measure menu as follows:
H
Select Measurement for CH1
Measure
H
Gating
Off
Data Pulse Width
Adjustment
Содержание LTA7P Series
Страница 4: ......
Страница 14: ...Service Safety Summary x TLA7Nx TLA7Px TLA7Qx Logic Analyzer Module Service Manual...
Страница 22: ...Introduction xviii TLA7Nx TLA7Px TLA7Qx Logic Analyzer Module Service Manual...
Страница 86: ......
Страница 96: ...Logic Analyzer Module Adjustment Procedures 5 10 TLA7Nx TLA7Px TLA7Qx Logic Analyzer Module Service Manual...
Страница 148: ...Troubleshooting 6 40 TLA7Nx TLA7Px TLA7Qx Logic Analyzer Module Service Manual...
Страница 154: ...Electrical Parts List 8 2 TLA7Nx TLA7Px TLA7Qx Logic Analyzer Module Service Manual...
Страница 170: ...Mechanical Parts List 10 14 TLA7Nx TLA7Px TLA7Qx Logic Analyzer Module Service Manual...
Страница 171: ......
Страница 172: ......