![Tektronix DAS 9221 Option 04 Скачать руководство пользователя страница 95](http://html1.mh-extra.com/html/tektronix/das-9221-option-04/das-9221-option-04_user-manual_1077973095.webp)
Reference
3–14
DAS System User Manual
To define external signal events, use the Signal Definition overlay. If you select
External in the Components field, the following new fields appear that allow you
to establish the logic convention for signal events on the external event lines:
H
Slot field. Lists the location (slot number) of all expansion modules in your
mainframe(s). This field is for information purposes only, you cannot make
selections here.
H
Card field. Lists the expansion modules in your mainframe(s); these modules
contain external event lines. This field is for information purposes only, you
cannot make selections here.
H
Event Out and Event In fields. Each expansion module in your mainframe(s)
contains an external event input line and an external event output line. Use
this field to define the logic conventions of signals being sent from the
output line to an external device. Selections are Unused, Hi True, and Lo
True. (If the event output line is being used by another signal event, Unavail.
will appear indicating that you cannot make a selection.)
The Correlation Definition overlay lets you specify correlation from two
acquisition modules in the current cluster. To call this overlay, select function
key F4: DEFINE CORRELATN in the Cluster Setup menu.
Data acquired by time-correlated modules can be viewed in a single combined
display menu.
Only clustered modules can be time-correlated. Figure 3–7 shows a simple
correlation application for one cluster. In this example, two acquisition modules
have been time correlated. This means that data acquired by each of the modules
is time aligned, allowing you to determine where each data sample occurred
relative to each other sample in time.
The fields in the Correlated Module column let you select modules you want to
correlate. Press the right mouse button while pointing at the blank field to view a
list of choices. If you want to add another module to the list, select function key
F7: ADD CORR; a blank field will appear below the current list. Available
selections are the acquisition modules in the cluster (pattern generation modules
cannot be correlated).
Correlation Definition
Overlay
Содержание DAS 9221 Option 04
Страница 4: ......
Страница 6: ......
Страница 16: ...Table of Contents x DAS System User Manual ...
Страница 20: ...General Safety Summary xiv DAS System User Manual ...
Страница 23: ......
Страница 48: ......
Страница 81: ......
Страница 156: ......
Страница 166: ...Appendix B Accessories B 4 DAS System User Manual ...
Страница 178: ...Appendix C Error Messages C 12 DAS System User Manual ...
Страница 238: ...Appendix F User Service F 26 DAS System User Manual ...
Страница 249: ......
Страница 266: ......
Страница 275: ......
Страница 276: ......