![Tektronix DAS 9221 Option 04 Скачать руководство пользователя страница 209](http://html1.mh-extra.com/html/tektronix/das-9221-option-04/das-9221-option-04_user-manual_1077973209.webp)
Appendix E: Configuration Utility
DAS System User Manual
E–9
This selection is only valid if your system has a 92C02 GPIB Module installed.
Selecting item P from the Main menu lets you set the GPIB port address
assigned to the instrument when it is used in a GPIB network. Legal values are
Off line and addresses 0 through 30. When the value is set to Off line, the
instrument is prevented from responding to any GPIB activity.
Enter a new value in the range of 0 to 30 or –1 for Off Line. Press the Return key
to retain the current value.
If you have a Tektronix X terminal, you can use the Configuration utility to
update the terminals internal Flash ROM. Updating the Flash ROM is only
necessary when the terminal’s software or fonts require updating with a new
version. You may also need to update the Flash ROM as a result of any service
work done to the terminal. If you desire to update the Flash ROM, you first must
set the network configuration parameters for the instrument using the Configura-
tion utility.
NOTE
. You do not need to update the Flash ROM in the terminal to change the
Internet address. Use the other selections in the Configuration Utility Main
menu to update the internet information for the instrument. Update the terminal
internet information in the Boot Monitor. Internet addresses and other network-
ing parameters are normally assigned by your system administrator.
After setting the parameters, select item U to begin the Flash ROM update
process. You are asked to confirm your actions before starting the operation.
Enter y to confirm your actions.
A series of messages are displayed. When the operation is ready to load the X
terminal software, information appears on the screen. Follow the steps listed
below and the displayed instructions to update the Flash ROM. The following
steps assume that you have a 9202XT terminal; the procedure is similar for other
TekXpress X terminals.
Read the entire Flash ROM procedure on the terminal screen before continuing.
To return to the start of the procedure on the screen, press the Return key.
NOTE
. If your X terminal is not a 9202XT or 9203XT Terminal (XP17 or XP18),
skip to Step 2.
1. Before starting the Flash Update procedure, information regarding the
software compression is displayed. Follow the instructions on the screen to
make the appropriate selections for your Flash ROM configuration.
2. Information about Step 1 of the Flash ROM procedure is displayed. Read the
information carefully before proceeding.
Set GPIB Port Number
Update Terminal Flash
ROM
Содержание DAS 9221 Option 04
Страница 4: ......
Страница 6: ......
Страница 16: ...Table of Contents x DAS System User Manual ...
Страница 20: ...General Safety Summary xiv DAS System User Manual ...
Страница 23: ......
Страница 48: ......
Страница 81: ......