Reference
3–20
DAS System User Manual
H
Compare Mask column. This column specifies a global mask for that portion
of the data indicated by the group name to the left. Values translating to a
binary 1 mean “use this bit in the comparison,” and those translating to a
binary 0 mean “ignore this bit.” Select function key F3: DEFAULT MASK
to reset this field to the default value (compare all bits).
Function key F3: DEFAULT MASK resets the comparison mask for the current
acquisition memory to the default condition, (all binary ones). If the mask fields
are not present, this function key will not be present.
Function key F5: RESTORE AUTORUN displays a list of saved definitions; the
one you select will be restored. Function key F6: DELETE AUTORUN displays
a list of saved definitions; the one you select will be deleted. The fields will not
be present if there are no saved definitions.
Function key F7: SAVE AUTORUN displays a field where you can enter the file
name to save the definition under.
System Monitor Menu
The System Monitor menu displays the current status of the modules in the
system. The current selected cluster and modules are highlighted in yellow. The
System Monitor menu, shown in Figure 3–10, is not interactive. The display is
for information purposes only.
The status column displays a status message for each module or cluster. Possible
messages are Idle, Waiting For Enable, Waiting For Trigger, Waiting For
Stop/Store, Waiting For Stop, and Running. Possible Autorun messages are Idle
or Running followed by an Autorun count.
The Modules column lists all modules and clusters in the system.
Function key F1 starts or stops the selected module or cluster. If none of the
modules in the cluster are running, this legend will read START (Cluster name);
if any of the modules in the cluster are running, this legend will read STOP
(Cluster name). The function key toggles the same way for an unclustered
module. The function key is not present if you have selected a reference memory.
Содержание DAS 9221 Option 04
Страница 4: ......
Страница 6: ......
Страница 16: ...Table of Contents x DAS System User Manual ...
Страница 20: ...General Safety Summary xiv DAS System User Manual ...
Страница 23: ......
Страница 48: ......
Страница 81: ......
Страница 156: ......
Страница 166: ...Appendix B Accessories B 4 DAS System User Manual ...
Страница 178: ...Appendix C Error Messages C 12 DAS System User Manual ...
Страница 238: ...Appendix F User Service F 26 DAS System User Manual ...
Страница 249: ......
Страница 266: ......
Страница 275: ......
Страница 276: ......