Getting Started
2715 User Manual
2–13
CARRIER LEVEL: CURRENT
CHAN 8 24–OCT–91 19:33:08
TEKTRONIX
JOHN SMITH
VISUAL 8.7DBMV @ 181.240072MHZ
AURAL
−
16.4DBC @ +4.499988MHZ
PRESS ”W” TO CONT, ”Z” TO ABORT
Figure 2–3: Typical Measurement Result Display
This procedure shows you how to verify the frequency and amplitude of the
calibration signal. Although the calibration signal is used, the measurement
technique is the same for any continuous signal. In the process, you will learn to
use three of the most important controls on the spectrum analyzer and to confirm
that the major functions of the spectrum analyzer are operating correctly.
1. Press [UTIL] [1] [1] to recall FACTORY DEFAULT POWER-UP settings.
The factory defaults set the RF attenuation to 50 dB. This affords the most
protection to the spectrum analyzer, because any signal at the input
undergoes maximum attenuation before reaching the power-sensitive mixer
circuit. We recommend that you use this setting when connecting unknown
signals to the spectrum analyzer.
2. Press [CATV/APPL] [8] [0] to disable the CATV mode.
3. Press [MAX] then [AUTO] (in the RES BW block) to enable maximum
span and AUTO RES BW.
The span goes to 180 MHz per division, and the resolution bandwidth goes
to 5 MHz. This is maximum span and is indicated by the word MAX in the
span readout. This is the safe setting for introducing new signals. It enables
you to view the entire measurement range (1.8 GHz) of the spectrum
analyzer. If a smaller span is used, large signals can be present off-screen.
Making Your First
NonCATV Measurement
Содержание 2715
Страница 4: ......
Страница 12: ...Table of Contents viii 2715 User Manual ...
Страница 18: ...Preface xiv 2715 User Manual ...
Страница 19: ...Introduction ...
Страница 20: ......
Страница 24: ...Introduction 1 4 2715 User Manual ...
Страница 25: ...Getting Started ...
Страница 26: ......
Страница 46: ...Getting Started 2 20 2715 User Manual ...
Страница 47: ...Operating Basics ...
Страница 48: ......
Страница 70: ...Operating Basics 3 22 2715 User Manual ...
Страница 71: ...Dedicated Controls ...
Страница 72: ......
Страница 108: ...Dedicated Controls 4 36 2715 User Manual ...
Страница 109: ...CATV Measurements ...
Страница 110: ......
Страница 181: ...Spectrum Analyzer Menus ...
Страница 182: ......
Страница 274: ...Spectrum Analyzer Menus 6 92 2715 User Manual ...
Страница 275: ...Appendices ...
Страница 276: ......
Страница 302: ...Appendix B Broadcast AM FM and TV Signal Sources B 2 2715 User Manual ...
Страница 318: ...Appendix C System Messages C 16 2715 User Manual ...
Страница 334: ...Appendix E External Input and Output E 12 2715 User Manual ...
Страница 339: ...Glossary and Index ...
Страница 340: ......
Страница 359: ......
Страница 360: ......