DSET00 and SET0BU are special files. They are created automatically by the
2715 and contain the D-register settings used when the 2715 was last turned off.
SET0BU is a backup in case DSET00 is corrupted during a power-down or
power-up cycle.
Other temporary files may also be created by the 2715 for internal purposes.
Files you wish to preserve such as waveform, settings, or UDP files can be
protected from accidental erasure in several ways. UDP files can be selectively
protected from the USERDEF menu, while all settings files can be protected by
pressing [UTIL] [4] [5].
However, to protect an individual file in the file system, first determine its file
number by viewing the file directory by pressing [UTIL] [4] [6]. The number is
listed under the FID column in the directory. Return to the System Configuration
menu and select item 7, PROTECT FILE. Following the on-screen prompt, enter
the number of the file you want to protect. Confirm your selection by pressing
[W]. It is now impossible to delete the file without first unprotecting it.
Repeat the foregoing process to unprotect a previously protected file. The
process constitutes a toggle that alternately protects and unprotects the desig-
nated file.
NOTE
. Unless you have specific reasons for doing otherwise, do not protect
system parameter and normalization files (see Table 5–6 on page 5–15). Doing
so may prevent the 2715 from carrying out its normal functions or updating
data.
If you are in doubt as to which options are installed in your instrument, press
[UTIL] [4] [9].
The resulting display begins by listing the instrument’s firmware version and the
Tektronix copyright. Below that, two columns list the options installed in your
2715. You will see a readout similar to the following:
NVM 1 12.88
NVM 2 12.88
GPIB
RS-232
The number following NVM (nonvolatile memory) is for internal Tektronix use
only and of no value to the user. The list will vary according to the options
actually installed in your instrument.
GPIB and RS-232 both appear regardless of which is physically installed in the
2715. See Configuring the Communications Port on page 6–67 for additional
information.
Protecting Files
Confirming Installed
Options
Содержание 2715
Страница 4: ......
Страница 12: ...Table of Contents viii 2715 User Manual ...
Страница 18: ...Preface xiv 2715 User Manual ...
Страница 19: ...Introduction ...
Страница 20: ......
Страница 24: ...Introduction 1 4 2715 User Manual ...
Страница 25: ...Getting Started ...
Страница 26: ......
Страница 46: ...Getting Started 2 20 2715 User Manual ...
Страница 47: ...Operating Basics ...
Страница 48: ......
Страница 70: ...Operating Basics 3 22 2715 User Manual ...
Страница 71: ...Dedicated Controls ...
Страница 72: ......
Страница 108: ...Dedicated Controls 4 36 2715 User Manual ...
Страница 109: ...CATV Measurements ...
Страница 110: ......
Страница 181: ...Spectrum Analyzer Menus ...
Страница 182: ......
Страница 274: ...Spectrum Analyzer Menus 6 92 2715 User Manual ...
Страница 275: ...Appendices ...
Страница 276: ......
Страница 302: ...Appendix B Broadcast AM FM and TV Signal Sources B 2 2715 User Manual ...
Страница 318: ...Appendix C System Messages C 16 2715 User Manual ...
Страница 334: ...Appendix E External Input and Output E 12 2715 User Manual ...
Страница 339: ...Glossary and Index ...
Страница 340: ......
Страница 359: ......
Страница 360: ......