CATV Measurements
2715 User Manual
5–65
To achieve the best amplitude measurement accuracy, your test generator must
produce a signal whose spectral density is the same at each test frequency.
Ideally, all signals should have equal amplitude and burst duration (for multi-
burst signals) or uniform sweep rate (for swept signals).
Many generators do not meet standards for flat spectral density. Further, test
signals carried on program video may not be flat. Therefore, if in-channel
response measurements yield excessive response deviations, check the flatness of
the test signal being used (if possible). This might be done either at RF or at
baseband (depending on circumstances) at the head end of the cable system. If
such a check reveals a problem, it is reasonable to use the head end data to
compensate the field data for the in-channels errors measured at the head end.
The following procedure shows how to make an interactive in-channel response
measurement.
1. Press CATV/APPL to call up the CATV MEASUREMENTS menu. See
Figure
Ă
5–1.
2. Press [9] [7] to select the IN-CHANNEL RESPONSE measurement menu.
This gives you the following options:
0
RUN IN-CHAN RESP
1
STORE CURRENT RESULTS
2
DISPLAY RESULTS
3
PRINT CURRENT RESULTS (RS-232 Only)
4
PRINT STORED RESULTS (RS-232 Only)
5
IN-CHAN RESP SETUP
6
TEST SIGNAL LINE NUMBER
7
IN-SERVICE
9
LEAVE IN-CHAN RESP
NOTE
. If you attempt the in-channel response measurement based on VITS or
ghost-cancelling signals carried on the program video, strong, periodic signals
in the video waveform may corrupt the measurement. Choose the in-service basis
with menu item [7] to resolve this problem.
If you are not measuring in-service, it is recommended that you have a test signal
generator warmed up and connected to the on-line switcher.
3. Press [5] [0] to select the Interactive mode.
4. Press [BKSP] [0] to run the measurement.
If you are not running the test in-service, the instrument pauses and prompts
you to enable a full-field test signal (Multiburst or Line Sweep).
Running the Interactive
Measurement
Содержание 2715
Страница 4: ......
Страница 12: ...Table of Contents viii 2715 User Manual ...
Страница 18: ...Preface xiv 2715 User Manual ...
Страница 19: ...Introduction ...
Страница 20: ......
Страница 24: ...Introduction 1 4 2715 User Manual ...
Страница 25: ...Getting Started ...
Страница 26: ......
Страница 46: ...Getting Started 2 20 2715 User Manual ...
Страница 47: ...Operating Basics ...
Страница 48: ......
Страница 70: ...Operating Basics 3 22 2715 User Manual ...
Страница 71: ...Dedicated Controls ...
Страница 72: ......
Страница 108: ...Dedicated Controls 4 36 2715 User Manual ...
Страница 109: ...CATV Measurements ...
Страница 110: ......
Страница 181: ...Spectrum Analyzer Menus ...
Страница 182: ......
Страница 274: ...Spectrum Analyzer Menus 6 92 2715 User Manual ...
Страница 275: ...Appendices ...
Страница 276: ......
Страница 302: ...Appendix B Broadcast AM FM and TV Signal Sources B 2 2715 User Manual ...
Страница 318: ...Appendix C System Messages C 16 2715 User Manual ...
Страница 334: ...Appendix E External Input and Output E 12 2715 User Manual ...
Страница 339: ...Glossary and Index ...
Страница 340: ......
Страница 359: ......
Страница 360: ......