Issue/Rev. 0.1 (11/18) ║ MNKS025 • Page 103
4. GOST calculation outputs
Select Run Data from Main Menu
Select GOST Calculations Output to view Run Time Data to verify input and output
values.
a. User Screens
i. Run Data / GOST Calculation Output
c. Variables
i. Gas compressibility
1. Line conditions
2.
Reference
conditions
ii. Adiabatic Exponent (k)
iii. Speed of sound
iv. Viscosity (dynamic)
v. Density at line conditions
vi. Isobaric heat value (superior)
vii. Isobaric heat value (inferior)
viii. Derived outputs
1. Mass flow rate
2. Compressibility ratio
3. Viscosity (kinematic)
4. Correction factor
5. Standard flow rate
MPU Series C I/O/M Manual