7.3.1.4. Display Connections
The connections setting is used to connect to the desired ultrasonic flowmeter.
Primary URL
– This fixes a target IP/URL address that the Display will first attempt to
connect to upon startup of the unit. In order to configure this value the IP address of
the ultrasonic flowmeter must be known.
Primary Timeout
– Maximum time allowed for the primary URL connection attempt, in
seconds. The URL connection attempt can be skipped by setting a zero timeout.
Device Serial Number
– The unique serial number assigned to the ultrasonic meter
control board. The Ultra series flowmeter will broadcast this Serial Number over the net-
work in a way that the display unit can detect. When the display matches the configured
Serial Number to a device on the network it will form a connection. The ultrasonic meter
Serial Number will be displayed in the meter electronics box. This is the recommended
connection method to the ultrasonic flowmeter.
Device Timeout
– Maximum time allowed for the device Serial Number connection
attempt.
Secondary URL
– An alternate target IP/URL address - the display will attempt to
connect to. In order to configure this value the IP address of the ultrasonic flowmeter
must be known.
Secondary Timeout
– Maximum time allowed for the secondary URL connection at-
tempt, in seconds. The secondary URL connection attempt can be skipped by setting
a zero timeout.
Minimum Up Time
– A minimum time allowed since power up to allow attempting a
host connection. Setting this to a larger value (in seconds) may be needed if the dis-
play attempts to connect to its host before the host is ready to accept connections (for
example, if all instruments are turned on with the same power source, and the host
takes longer to boot up).
MPU Series C I/O/M Manual
Integrated Touch Screen Display
Содержание Smith Meter MPU 1600c
Страница 10: ...Page 10 MNKS025 Issue Rev 0 1 11 18 Page intentionally left blank ...
Страница 34: ...Page 34 MNKS025 Issue Rev 0 1 11 18 Page intentionally left blank ...
Страница 38: ...Page 38 MNKS025 Issue Rev 0 1 11 18 Page intentionally left blank ...
Страница 98: ...Page 98 MNKS025 Issue Rev 0 1 11 18 Page intentionally left blank ...
Страница 106: ...Page 106 MNKS025 Issue Rev 0 1 11 18 Page intentionally left blank ...
Страница 112: ...Page 112 MNKS025 Issue Rev 0 1 11 18 Page intentionally left blank ...
Страница 119: ...Issue Rev 0 1 11 18 MNKS025 Page 119 Page intentionally left blank ...