Page 116 • MNKS025 ║ Issue/Rev. 0.1 (11/18)
Parameter
Name
Menu
Range
Nominal
Description
An In Low Limit
Inputs and
Outputs
3.8 mA
12 mA
3.8 mA
Electrical input below this limit will
not be allowed.
RTD In
Temperature
Offset
Inputs and
Outputs
-10 C
+10 C
0 C
Temperature offset to apply to the
measured temperature.
RTD Input High
Limit
Inputs and
Outputs
100 Ohms
168.4783 Ohms
168.4783 Ohms
Electrical input above this limit will
not be allowed.
RTD Input Low
Limit
Inputs and
Outputs
76.3278 Ohms
100 Ohms
76.3278 Ohms
Electrical input below this limit will
not be allowed.
Line
Temperature
Input Mode
Modes
-fallback
-4-20mA input #1
-4-20mA input #2
-RTD input
-modbus
Default:
fallback
Data source for line temperature
used in compensations.
Line Pressure
Input Mode
Modes
-fallback
-4-20mA input #1
-4-20mA input #2
-modbus
Default:
fallback
Data source for line pressure used in
compensations.
Electronic Seal
State
Modes
-open
-sealed
Default:
open
Electronic seal state.
Line
Temperature
Fallback Value
Modes
-40 C
150 C
20 C typ.
Fallback value for line temperature
used in compensations.
Line Pressure
Fallback Value
Modes
0 bar(a)
250 bar(a)
5 bar(a) typ.
Fallback value for line pressure used
in compensations.
Number of Cal
Nodes
Transducer
0
3
0
Number of transducer calibration
nodes.
Correction
Mode
Transducer
Mode selection for transducer
calibration algorithm.
Node Pressure
Transducer
0 bar(a)
250 bar(a)
Per transducer calibration
Node calibration point pressure.
Node
Temperature
Transducer
-40 C
150 C
Per transducer calibration
Node calibration point temperature.
Flow Rate
Node
Calibration
(no limits)
Per calibration
Flow rate for this calibration node.
Node Meter
Factor
Calibration
0.9
1.1
Per calibration
Meter factor for this calibration node.
Node A coeff
Factory
Settings
Node A coeff.
Node B Coeff
Factory
Settings
Node B coeff.
VPC X
Factory
Settings
1.0
4.0
Per calibration
Velocity profile correction node X
value.
VPC Meter
Factor
Factory
Settings
0.9
1.1
Per calibration
Meter factor for this calibration node.
ReNo Node
VPC X
Factory
Settings
1.0
4.0
Per calibration
Velocity profile correction node X
value.
ReNo Node
Reynolds
Number
Factory
Settings
10
10000000
Per calibration
Corresponding Reynolds number.
MPU Series C I/O/M Manual
Appendix A – Description of Legally Relevant Parameters
Содержание Smith Meter MPU 1600c
Страница 10: ...Page 10 MNKS025 Issue Rev 0 1 11 18 Page intentionally left blank ...
Страница 34: ...Page 34 MNKS025 Issue Rev 0 1 11 18 Page intentionally left blank ...
Страница 38: ...Page 38 MNKS025 Issue Rev 0 1 11 18 Page intentionally left blank ...
Страница 98: ...Page 98 MNKS025 Issue Rev 0 1 11 18 Page intentionally left blank ...
Страница 106: ...Page 106 MNKS025 Issue Rev 0 1 11 18 Page intentionally left blank ...
Страница 112: ...Page 112 MNKS025 Issue Rev 0 1 11 18 Page intentionally left blank ...
Страница 119: ...Issue Rev 0 1 11 18 MNKS025 Page 119 Page intentionally left blank ...