Fiber Optics Communication:
This device contains a fiber optic Ethernet Transceiver
module; any fiber optics device(s) connected to this device through the connecting fiber
optic cable must be suitable for the location in which it is (they are) installed and any
locations where the fiber optic cables are run, with respect to both electrical circuits and
optical radiation, for ATEX and/or IEC Ex installations.
Special Conditions for Safe Use
CAUTION:
To prevent ignition of hazardous atmospheres and to prevent electrical
shock, disconnect from supply circuits before opening, keep tightly closed when circuits
are in operation.
WARNING:
The enclosure contains an internal battery-powered circuit. To prevent
ignition of hazardous atmospheres, do not open enclosure unless area is known to be
non-hazardous. Substitution of components may impair intrinsic safety and op is.
Marking
Equipment
Certificate
Ex d IIB
T4 – T6 IP66
Tamb = -40°C to +70°C
Ultrasonic
DEMKO 05 ATEX
Ultrasonic Transducer
System
DEMKO 09 ATEX 0907098X
IECEx UL 09.0023X
Ex d ia op is IIB T5 Gb
(Um=250v) IP66
Tamb = -40°C to 60°C
Ultrasonic Meter Control
(UCM) w/o display
DEMKO 13 ATEX 1204991X
IECEx UL 13.0019X
Ex d op is IIB T5 Gb IP66
Tamb = -40°C to 60°C
Ultrasonic Meter Control
(UCM) w/o display
Ex d ib IIB T5 Gb IP66
Tamb = -40°C to 60°C
Remote Mounted Display:
Touch Screen Control
Interface (TCI)
Marking
Equipment
Certificate
Ex db op is IIB + H2 T5
Tamb = -50°C to +60°
Aluminum: UMH-H-…
Stainless steel: UMHX-H-…
BVS 17 ATEX E 052 X
IECEx BVS 17.0046X
3.9.1.
Installation of Cables
Due to customer or location specific requirements, the cables for communication and
power supply lines are usually not a part of the delivery. However, the technical speci-
fications for the cables MUST be followed. Prior to the installation, these requirements
must be checked.
The number of and types of cables are dependent on which version or options that are
delivered. A set of wiring diagrams are available covering the different options. Project
specific wiring diagrams may also be available. Cable installation and connection must
be done by professionals with the required skills and certificates.
DO NOT SWITCH POWER ON
until the installation is checked and approved by sup-
plier. Any damage caused by unauthorized operation will void the warranty.
Содержание Smith Meter MPU 1600c
Страница 10: ...Page 10 MNKS025 Issue Rev 0 1 11 18 Page intentionally left blank ...
Страница 34: ...Page 34 MNKS025 Issue Rev 0 1 11 18 Page intentionally left blank ...
Страница 38: ...Page 38 MNKS025 Issue Rev 0 1 11 18 Page intentionally left blank ...
Страница 98: ...Page 98 MNKS025 Issue Rev 0 1 11 18 Page intentionally left blank ...
Страница 106: ...Page 106 MNKS025 Issue Rev 0 1 11 18 Page intentionally left blank ...
Страница 112: ...Page 112 MNKS025 Issue Rev 0 1 11 18 Page intentionally left blank ...
Страница 119: ...Issue Rev 0 1 11 18 MNKS025 Page 119 Page intentionally left blank ...