6

TEC-67398-2

 

Technical description Prizrak-5S BT

Slim-tag

Tag 

– is an electronic key allowing to authenticate an authorized vehicle driver. You must always carry a tag with 

you while operating a vehicle. The immobilizer system will automatically detect the tag before the vehicle motion 

begins. A confirmatory trill will sound when a tag is detected.

Any modification of Prizrak 5S immobilizer may be upgraded with tags (up to 8 tags in total, including no more 

than 4 smartphone tags). The default settings of Prizrak 5S/BT allow to utilize a tag for authentication as soon as 

it has been registered without having to change any settings even though tags are not included in the standard 

immobilizer set.

• 

One tag can’t be registered into several immobilizer systems at the same time.

• 

You may use your smartphone for authentication as well.

Replacing the tag battery

Five short beeps five short beeps following after authentication mean that the battery inside the tag must be 

replaced. The battery type is CR-2025. Visit a workshop to have the tag battery replaced by an installer or do it 

yourself.

Registering new Slim tags

Register all desired tags within one procedure. The tags that are not taking part in the registration process will 

be erased form the immobilizer's memory.

Registration sequence:

1. 

Select one of the tags that will be used for authentication. Disassemble all the other tags and take the 

batteries out of them beforehand. Take the batteries out of each tag in case if a tag is not required for 

authentication (e.g. for authentication is used PIN code or PUK code).

2. 

Carry out an authentication procedure. The immobilizer will emit the confirmatory trill indicating that the 

authentication is successful.

3. 

Press and release the programming button 12 times, the immobilizer will emit 4 short beeps.

4. 

Press and release the programming button 10 times, the alarm will emit a series of 1 long beeps.

5. 

Press and hold the brake pedal, the immobilizer will indicate the number of already registered tags by series 

of beeps. The number of emitted beeps within one series indicates the total number of registered tags in the 

system’s memory.

6. 

Place a battery into one of the tags. Wait for short intermittent beeps signifying that the tag registration 

procedure has started. After a tag has been successfully registered the immobilizer will indicate the total 

number of tags programmed into the system’s memory by a series of buzzer beeps. Make sure the number 

of emitted beeps matches the number of all tags registered into the system.

7. 

Insert the battery into the next tag, wait until the tag is registered, repeat the steps described above if more 

tags are planned to be registered. 

8. 

Release  the  brake  pedal  and  turn  the  vehicle’s  ignition  OFF  after  the  last  tag  has  been  registered,  the 

confirmatory trill will follow.

• 

It is allowed to enter the default PIN code «2» with the integrated programming button (reset button) for 

authentication if the vehicle hasn’t travelled 10 km after the immobilizer installation and if the default 

PIN code hasn’t been already changed.

• 

It is possible to register up to 8 tags into one immobilizer module.

• 

A tag will fail to register if the authentication method «PIN code» is set.

Use an edge of

a plastic card

for opening convenience

Use only

unexpired batteries

of high quality!

Open here

Strictly

observe the 

polarity

3V

CR 2025

Содержание Prizrak 5S/BT

Страница 1: ...PROTECTION AGAINST PROFESSIONAL CARJACKING IMMOBILIZER TECHNICAL DESCRIPTION...

Страница 2: ...with a vehicle 12 2nd step Selecting and programming vehicle buttons 13 3rd step Configuring the Immobilizer features 13 Configuring the immobilizer hardware functions 14 Configuring the programmable...

Страница 3: ...g the user s se cret Bluetooth code The Installer mode of the application was specially designed for this purpose The barcode located on the plastic card supplied with the device should be used to pai...

Страница 4: ...rd lights and driver warning beeps will activated for 15 seconds Herewith AntiHiJack allows to start the vehicle s engine but prevents driving the vehicle according to the same algorithms as the Immob...

Страница 5: ...scratch off the protective film of the Bluetooth code however it is possible to test the immobilizer performance after installing it by using a temporary code the code to register a smartphone as the...

Страница 6: ...rry out an authentication procedure The immobilizer will emit the confirmatory trill indicating that the authentication is successful 3 Press and release the programming button 12 times the immobilize...

Страница 7: ...vehicle has travelled 10 km after installing the system the authentication method can only be changed after entering the secret PUK code located on the plastic card supplied with the device Futhermor...

Страница 8: ...ur installation technician to find out the list of available buttons for your vehicle Enter PIN code While entering one of the PIN digits keep in mind that pressings duration and pauses be tween figur...

Страница 9: ...ce mode Quickly engaging maximum security Two circuit security mode increases the anti theft possibilities of the immobilizer system in case if the tag is stolen or lost Engage the second security cir...

Страница 10: ...ock control The system s anti thieft capabilities may be improved by installing an additional electro mechanical hood lock and programming the alarm to latch the hood when arming the vehicle and to un...

Страница 11: ...nt is described in the Table 3 Connectors pin numeration is shown in figure 1 Inputs outputs adjustment is carried out through the programming menu see section Hardware functions configuration 12 7 1...

Страница 12: ...pause 2 short beeps 4 sec The module will indicate the detected group and subgroup circularly 3 times Manual interfacing This interfacing method might be necessary only in exceptional cases A group a...

Страница 13: ...corresponding po larity and assign the feature 6 refer to the Table 7 to the programmable inputs These buttons may be used as the programming button or for entering a PIN code even if the resistive o...

Страница 14: ...n It is also possible to assign to these inputs any feature listed in the Table 7 if the option 6 is configured for the value 2 7 Hazard lights control method 4 1 by connecting to a pulse hazard light...

Страница 15: ...short beeps 25 two long and 5 short beeps It is allowed to enter PIN code 2 with the programming button if a vehicle hasn t yet travelled 10 km after the installation and the default PIN code hasn t b...

Страница 16: ...yellow 9 wires configuration CAN bus or Output 1 1 data bus CAN2 2 programmable output 5 Brown wire 3 function configu ration This wire function is dependant on the value of the option 4 Data bus CAN2...

Страница 17: ...lowed to en ter PIN code 2 with the programming button if a vehicle hasn t yet travelled 10 km after the installation and the default PIN code hasn t been changed The immobilizer system will automatic...

Страница 18: ...monitoring If it is not possible to read the Ignition status data out of the vehicle s CAN bus for exam ple when a vehicle s specific electrical circuits are being interrupted then this immobilizer i...

Страница 19: ...en only those doors you may do it beforehand that are supposed to be indicated on that output the doors you don t want to be indicated should be closed Apply the brake pedal again and keep it pressed...

Страница 20: ...ed if the engine is running and the vehicle s speed is less than 15 km h Yes 18 Rear parking sensors control power supply A constant level signal is formed if the engine is running the gear lever is s...

Страница 21: ...immobilizer is interfaced with a vehicle but also may be programmed manually if needed Yes 34 CDL unlocking alternative control A pulse is formed to unlock the power door locks with a double wire cont...

Страница 22: ...on hereinafter referred to as PB The immobilizer emits audible signals hereinafter beeps to indicate the current state of a setting being programmed In case if the option number or the option value co...

Страница 23: ...system s memory 5 To delete the smartphone tags from memory still hoding the brake pedal down press and release the programming button 1 time the confirmation trill followed after that signifies that...

Страница 24: ...ll immobilizer features to the default settings In case if the immobilizer is not installed on a vehicle The reset can be carried out in 3 ways 1 Using the built in button provided that the factory PI...

Страница 25: ...ing procedure for a certain car may be found out in the Integrator https int tecel ru 5 Change the factory PIN code 6 Inform the vehicle s owner which particular button has been assigned as the progra...

Страница 26: ...ure allows to quickly analyze the data available on the vehicle s CAN bus and adjust connection scheme if required The built in LED is used for indication check The immobilizer connection diagram The...

Страница 27: ...rizrak 5S BT Mark in the picture the immobilizer ele ments installation place This may help to quickly find them later The immobilizer elements installation scheme in a vehicle Keep this scheme out of...

Страница 28: ...ble beeps hereinafter beeps It is allowed to enter PIN code 2 with the programming button if a vehicle hasn t yet travelled 10 km after installing the system and the default PIN code hasn t been chang...

Страница 29: ...ation adjustment 3 Output 4 1 alert warning signals to siren 2 en gine locking normally closed NC relay control 3 programmable output refer to the option 8 4 electromechanical hood lock latching 8 The...

Страница 30: ...luetooth using an adapter TEC prog USB Bluetooth and follow the displayed instructions Cancelling registration if the main Immobilizer module is not available 1 Disconnect the module from power 2 Conn...

Страница 31: ...1 Quick reference card 1 Owner s guide 1 Warranty card 1 Wiring diagram 1 Packing 1 Technical specifications and operating conditions Parameter Value Power supply voltage V 9 15 Maximum current drain...

Страница 32: ...www tecel ru...