16
TEC-67398-2
Technical description Prizrak-5S BT
Configuring the programmable inputs/outputs (menu 11)
The code to enter the menu —
11, confirmation
— 6 beeps. The default values are highlighted.
Table 6. Programmable inputs/outputs configuration
№
Wire colour and
description
(wire № in the con
-
nector)
Available
operation modes
Default
value
The selected value. Commentary
1
Grey/black input
configuration (1)
Input (-)
6
Depends on the option №6, menu 10.
Wired button.
May be assigned one of the features
from the Table 7 «Programmable inputs features»
2
Pink/green wire
configuration (2)
Input (+)
or Output (+)
1
1 — Programmable input (+);
2 — Programmable output (+)
3
PInk/green wire
function configu
-
ration (2)
1
Brake pedal position monitoring.
Any feature from
the table «Programmable inputs features» may be
assigned to this wire. The wire will be automatically
configured for «Vehicle’s CDL unlocking blockage
if a tag is not in range (NO relay control)» feature
(refer to the «Programmable outputs features», the
feature №30), in case if the option №2 of this menu
is setup for the value «2»; After this it is possible to
assign any other feater to this output if desired
4
Brown (3) and
brown/yellow (9)
wires configuration
CAN-bus
or Output (-)
1
1 — data-bus CAN2;
2 — programmable output (-)
5
Brown wire (3)
function configu
-
ration
—
This wire function is dependant on the value of the
option №4.
Data bus CAN2 (L).
If the option №4 is setup for value «2» then the
output will automatically configure for feature «The
output is not used» (refer to the table «Programma-
ble outputs features», the option №0). After that it
will be possible to assign to this output any feature
from the «Programmable outputs features» table 8
6
Brown/yellow (9)
wire function coin-
figuration
—
Data-bus CAN2 (H).
Depends on the value of the
option №4. If the option №4 is setup for value «2»
then the output will automatically configure for
feature «The output is not used» (refer to the table
«Programmable outputs features», the option №0).
After that it will be possible to assign to this output
any feature from the «Programmable outputs» table
7
Blue/red wire (5)
function configu
-
ration
Output (-)
or Output (+)
32
Hazard lights alternative control.
It is possible to assign any feature from the table
«Programmable outputs features»
8
Blue/red wire (5)
configuration
2
1 — Programmable output (+);
2 — Programmable output (-)
9
Grey/yellow (7)
wire function con-
figuration
Input (+)
6
It is dependant on the value of the option №6,
menu 10.
Wired button.
It is possible to assign any feature from the table
«Programmable inputs features»
Содержание Prizrak 5S/BT
Страница 1: ...PROTECTION AGAINST PROFESSIONAL CARJACKING IMMOBILIZER TECHNICAL DESCRIPTION...
Страница 32: ...www tecel ru...