Table 7.  The programmable inputs features

The programmable inputs and outputs of the immobilizer system might be configured for different features 

from the tables 7 and 8 respectively. Hence, the immobilizer functionality may be easily reconfigured according to 

specific needs of an installation technician. Furthermore, the programmable features of the immobilizer may be 

assigned to the inputs and outputs of the hood compartment unit HCU-230/BT. However, some of the features can't 

be implemented by the HCU-230/BT due to its hardware capabilities.

Name of the feature and description

Possibility to 

implement 

the feature by 

HCU-230/BT

1

Brake pedal position monitoring.

Might have to be connected to the brake pedal pin switch output in case if there is no brake 

pedal position data running on the vehicle’s CAN-bus (refer to the «Integrator»)

Yes

2

Hood position monitoring.

Is connected to the hood pin switch wire in case if there is no hood position data running 

on the vehicle’s CAN-bus

Yes

3

Driver’s door pin-switch input.

Is connected to the driver’s door pin-switch wire if the vehicle’s CAN-bus doesn’t contain 

data on the driver’s door status (refer to the «Integrator»)

Yes

4

Hood lock latching via HCU-230.

If a signal is applied to this pulse trigger impulse the immobilizer will send a command to 

the HCU-230 to latch an aftermarket electro-mechanical hood lock

Yes

5

Ignition monitoring.

If it is not possible to read the Ignition status data out of the vehicle’s CAN-bus (for exam-

ple, when a vehicle’s specific electrical circuits are being interrupted) then this immobilizer 

input must be connected to the vehicle’s wire with co12 volts when the Ignition is 

ON. After assigning this feature to any programmable input — the immobilizer stops ana-

lyzing such data on the CAN-bus.

In order to make the immobilizer analyze the ignition status data on the CAN-bus again, 

reprogram this input to any other feature or reset the immobilizer to the default settings

Yes

6

Wired button (buttons).

The feature is assigned to a programmable input(s) if it is necessary to connect the im-

mobilizer to the vehicle’s «wired» button(s) which are intended for use as the PIN code 

combination buttons in case if the are no «CAN-bus buttons» in a particular car. The pro-

grammable input that was configured as the «Wired button» input must be connected to 

the output of a positive or negative button (momentary push-button with NO contacts). 

Use the programmable inputs №1 (grey/black) and  №7 (grey/yellow) if you need to con

-

nect to «resistive» buttons

No

Table 8.  Programmable outputs features

Name of the feature and description

Possibility to 

implement 

the feature by 

HCU-230/BT

0

The output is not used. 

It doesn’t generate any signals or pulses

Yes

1

«Armed» status.

The output provides a constant level signal after the vehicle is armed by the OEM remote 

key (keyless entry system) until it is disarmed

Yes

2

Pulse after «Arming»

The output provides a pulse of  0,8 seconds upon arming the vehicle by the OEM remote 

key (keyless entry system)

Yes

Содержание Prizrak 5S/BT

Страница 1: ...PROTECTION AGAINST PROFESSIONAL CARJACKING IMMOBILIZER TECHNICAL DESCRIPTION...

Страница 2: ...with a vehicle 12 2nd step Selecting and programming vehicle buttons 13 3rd step Configuring the Immobilizer features 13 Configuring the immobilizer hardware functions 14 Configuring the programmable...

Страница 3: ...g the user s se cret Bluetooth code The Installer mode of the application was specially designed for this purpose The barcode located on the plastic card supplied with the device should be used to pai...

Страница 4: ...rd lights and driver warning beeps will activated for 15 seconds Herewith AntiHiJack allows to start the vehicle s engine but prevents driving the vehicle according to the same algorithms as the Immob...

Страница 5: ...scratch off the protective film of the Bluetooth code however it is possible to test the immobilizer performance after installing it by using a temporary code the code to register a smartphone as the...

Страница 6: ...rry out an authentication procedure The immobilizer will emit the confirmatory trill indicating that the authentication is successful 3 Press and release the programming button 12 times the immobilize...

Страница 7: ...vehicle has travelled 10 km after installing the system the authentication method can only be changed after entering the secret PUK code located on the plastic card supplied with the device Futhermor...

Страница 8: ...ur installation technician to find out the list of available buttons for your vehicle Enter PIN code While entering one of the PIN digits keep in mind that pressings duration and pauses be tween figur...

Страница 9: ...ce mode Quickly engaging maximum security Two circuit security mode increases the anti theft possibilities of the immobilizer system in case if the tag is stolen or lost Engage the second security cir...

Страница 10: ...ock control The system s anti thieft capabilities may be improved by installing an additional electro mechanical hood lock and programming the alarm to latch the hood when arming the vehicle and to un...

Страница 11: ...nt is described in the Table 3 Connectors pin numeration is shown in figure 1 Inputs outputs adjustment is carried out through the programming menu see section Hardware functions configuration 12 7 1...

Страница 12: ...pause 2 short beeps 4 sec The module will indicate the detected group and subgroup circularly 3 times Manual interfacing This interfacing method might be necessary only in exceptional cases A group a...

Страница 13: ...corresponding po larity and assign the feature 6 refer to the Table 7 to the programmable inputs These buttons may be used as the programming button or for entering a PIN code even if the resistive o...

Страница 14: ...n It is also possible to assign to these inputs any feature listed in the Table 7 if the option 6 is configured for the value 2 7 Hazard lights control method 4 1 by connecting to a pulse hazard light...

Страница 15: ...short beeps 25 two long and 5 short beeps It is allowed to enter PIN code 2 with the programming button if a vehicle hasn t yet travelled 10 km after the installation and the default PIN code hasn t b...

Страница 16: ...yellow 9 wires configuration CAN bus or Output 1 1 data bus CAN2 2 programmable output 5 Brown wire 3 function configu ration This wire function is dependant on the value of the option 4 Data bus CAN2...

Страница 17: ...lowed to en ter PIN code 2 with the programming button if a vehicle hasn t yet travelled 10 km after the installation and the default PIN code hasn t been changed The immobilizer system will automatic...

Страница 18: ...monitoring If it is not possible to read the Ignition status data out of the vehicle s CAN bus for exam ple when a vehicle s specific electrical circuits are being interrupted then this immobilizer i...

Страница 19: ...en only those doors you may do it beforehand that are supposed to be indicated on that output the doors you don t want to be indicated should be closed Apply the brake pedal again and keep it pressed...

Страница 20: ...ed if the engine is running and the vehicle s speed is less than 15 km h Yes 18 Rear parking sensors control power supply A constant level signal is formed if the engine is running the gear lever is s...

Страница 21: ...immobilizer is interfaced with a vehicle but also may be programmed manually if needed Yes 34 CDL unlocking alternative control A pulse is formed to unlock the power door locks with a double wire cont...

Страница 22: ...on hereinafter referred to as PB The immobilizer emits audible signals hereinafter beeps to indicate the current state of a setting being programmed In case if the option number or the option value co...

Страница 23: ...system s memory 5 To delete the smartphone tags from memory still hoding the brake pedal down press and release the programming button 1 time the confirmation trill followed after that signifies that...

Страница 24: ...ll immobilizer features to the default settings In case if the immobilizer is not installed on a vehicle The reset can be carried out in 3 ways 1 Using the built in button provided that the factory PI...

Страница 25: ...ing procedure for a certain car may be found out in the Integrator https int tecel ru 5 Change the factory PIN code 6 Inform the vehicle s owner which particular button has been assigned as the progra...

Страница 26: ...ure allows to quickly analyze the data available on the vehicle s CAN bus and adjust connection scheme if required The built in LED is used for indication check The immobilizer connection diagram The...

Страница 27: ...rizrak 5S BT Mark in the picture the immobilizer ele ments installation place This may help to quickly find them later The immobilizer elements installation scheme in a vehicle Keep this scheme out of...

Страница 28: ...ble beeps hereinafter beeps It is allowed to enter PIN code 2 with the programming button if a vehicle hasn t yet travelled 10 km after installing the system and the default PIN code hasn t been chang...

Страница 29: ...ation adjustment 3 Output 4 1 alert warning signals to siren 2 en gine locking normally closed NC relay control 3 programmable output refer to the option 8 4 electromechanical hood lock latching 8 The...

Страница 30: ...luetooth using an adapter TEC prog USB Bluetooth and follow the displayed instructions Cancelling registration if the main Immobilizer module is not available 1 Disconnect the module from power 2 Conn...

Страница 31: ...1 Quick reference card 1 Owner s guide 1 Warranty card 1 Wiring diagram 1 Packing 1 Technical specifications and operating conditions Parameter Value Power supply voltage V 9 15 Maximum current drain...

Страница 32: ...www tecel ru...

Отзывы: