20
TEC-67398-2
Technical description Prizrak-5S BT
13
The engine is running
A constant signal is formed while the engine is running, the signal will vanish as soon as
the engine is shutdown
Yes
14
Engine RPM
A pulse signal is formed with frequency of 1 pulse per second which is proportional to 20
revolutions per minute of the engine velocity speed. The reflected RPM are approximate,
not precised
No
15
Gear lever position
A constant signal is formed if the gear lever is shifted to a pre programmed position: for
AT and robotic transmissions can be programmed any gear lever position; for manual
transmission-only R position. Refer to the chapter «Sequence for programming inputs/
outputs (menu 11)» starting from the step 5.
After the brake pedal is pressed the immobilizer will indicate the current option value
twice in a series of 1 long beep and 5 short beeps, and then will start emitting short in
-
termittent beeps. Holding the brake pedal, shift the gear lever to a desired position (you
may shift the gear lever to a desired position beforehand). Release the brake pedal press
it again, the immobilizer will stop emitting short beeps and will indicate the current option
value (1 long beep and 5 short beeps). Release the brake pedal, the immobilizer will indi
-
cate the option number
Yes
16
The vehicle is moving
A constant level signal is formed if the vehicle’s speed exceeds 5-10 km/h (the speed
threshold depends on a vehicle model)
Yes
17
Front parking sensors control (power supply)
A constant level signal is formed if the engine is running and the vehicle’s speed is less
than 15 km/h
Yes
18
Rear parking sensors control (power supply)
A constant level signal is formed if the engine is running, the gear lever is shifted to «R»
and the vehcle speed is less than 15 km/h
Yes
19
Vehicle’s speed
A pulse signal is formed with frequency of 1 pulse per second which is proportional to
vehicle’s speed of 1 km/h. The reflected speed is approximate, not precised
No
20
Brake pedal
A constant level signal is formed when the brake pedal is down
Yes
21
Parking brake
A constant level signal is formed while the parking brake is engaged
Yes
22
Parking (marker) lights
A constant level signal is formed while the marker lights are ON
Yes
23
Timer channel («Comfort»)
A constant level signal is generated during a pre-selected time (10-60 sec.) after arming
the vehicle from the OEM remote or keyless entry system. The time may be set up by
intervals of 10 sec
Yes
24
Starter or OBDII diagnostics bus blocking (NC relay control)
A constant level signal is generated: while the CAN-bus is active before a vehicle owner
authentication procedure is completed and also when AntiHiJack is triggered
Yes
25
Pulse to latch an aftermarket hood lock
A pulse signal is formed during 0,8 sec.: after the vehicle is armed; when immobilizer,
AntiHiJack is triggered. The signal won’t be formed if the hood is up
Yes
26
Gas pedal locking (NC relay control)
The signals are generated to control a NC relay, which interrupts the gas pedal signal
wire allowing to decrease the vehicle speed and immobilize it at a safe speed if the
AntiHiJack has triggered
Yes
27
Service/valet mode status
The output generated a constant level signal while the service mode is active
Yes
Содержание Prizrak 5S/BT
Страница 1: ...PROTECTION AGAINST PROFESSIONAL CARJACKING IMMOBILIZER TECHNICAL DESCRIPTION...
Страница 32: ...www tecel ru...