TEC-67398-2

 

Technical description Prizrak-5S BT

13

The engine is running

A constant signal is formed while the engine is running, the signal will vanish as soon as 

the engine is shutdown

Yes

14

Engine RPM

A pulse signal is formed with  frequency of 1 pulse per second which is proportional to 20 

revolutions per minute of the engine velocity speed. The reflected RPM are approximate, 

not precised

No

15

Gear lever position

A constant signal is formed if the gear lever is shifted to a pre programmed position: for 

AT and robotic transmissions can be programmed any gear lever position; for manual 

transmission-only R position. Refer to the chapter «Sequence for programming inputs/

outputs (menu 11)» starting from the step 5.

After the brake pedal is pressed the immobilizer will indicate the current option value 

twice in a series of 1 long beep and 5 short beeps, and then will start emitting short in

-

termittent beeps. Holding the brake pedal, shift the gear lever to a desired position (you 

may shift the gear lever to a desired position beforehand). Release the brake pedal press 

it again, the immobilizer will stop emitting short beeps and will indicate the current option 

value (1 long beep and 5 short beeps). Release the brake pedal, the immobilizer will indi

-

cate the option number

Yes

16

The vehicle is moving

A constant level signal is formed if the vehicle’s speed exceeds 5-10 km/h (the speed 

threshold depends on a vehicle model)

Yes

17

Front parking sensors control (power supply)

A constant level signal is formed if the engine is running and the vehicle’s speed is less 

than 15 km/h

Yes

18

Rear parking sensors control (power supply)

A constant level signal is formed if the engine is running, the gear lever is shifted to «R» 

and the vehcle speed is less than 15 km/h

Yes

19

Vehicle’s speed

A pulse signal is formed with frequency of 1 pulse per second which is proportional to 

vehicle’s speed of 1 km/h. The reflected speed is approximate, not precised

No

20

Brake pedal

A constant level signal is formed when the brake pedal is down

Yes

21

Parking brake

A constant level signal is formed while the parking brake is engaged

Yes

22

Parking (marker) lights

A constant level signal is formed while the marker lights are ON

Yes

23

Timer channel («Comfort»)

A constant level signal is generated during a pre-selected time (10-60 sec.) after arming 

the vehicle from the OEM remote or keyless entry system. The time may be set up by 

intervals of 10 sec

Yes

24

Starter or OBDII diagnostics bus blocking (NC relay control)

A constant level signal is generated: while the CAN-bus is active before a vehicle owner 

authentication procedure is completed and also when AntiHiJack is triggered

Yes

25

Pulse to latch an aftermarket hood lock

A pulse signal is formed during 0,8 sec.: after the vehicle is armed; when immobilizer, 

AntiHiJack is triggered. The signal won’t be formed if the hood is up

Yes

26

Gas pedal locking (NC relay control)

The signals are generated to control a NC relay, which interrupts the gas pedal signal 

wire allowing to decrease the vehicle speed and immobilize it at a safe speed if the 

AntiHiJack has triggered

Yes

27

Service/valet mode status

The output generated a constant level signal while the service mode is active

Yes

Содержание Prizrak 5S/BT

Страница 1: ...PROTECTION AGAINST PROFESSIONAL CARJACKING IMMOBILIZER TECHNICAL DESCRIPTION...

Страница 2: ...with a vehicle 12 2nd step Selecting and programming vehicle buttons 13 3rd step Configuring the Immobilizer features 13 Configuring the immobilizer hardware functions 14 Configuring the programmable...

Страница 3: ...g the user s se cret Bluetooth code The Installer mode of the application was specially designed for this purpose The barcode located on the plastic card supplied with the device should be used to pai...

Страница 4: ...rd lights and driver warning beeps will activated for 15 seconds Herewith AntiHiJack allows to start the vehicle s engine but prevents driving the vehicle according to the same algorithms as the Immob...

Страница 5: ...scratch off the protective film of the Bluetooth code however it is possible to test the immobilizer performance after installing it by using a temporary code the code to register a smartphone as the...

Страница 6: ...rry out an authentication procedure The immobilizer will emit the confirmatory trill indicating that the authentication is successful 3 Press and release the programming button 12 times the immobilize...

Страница 7: ...vehicle has travelled 10 km after installing the system the authentication method can only be changed after entering the secret PUK code located on the plastic card supplied with the device Futhermor...

Страница 8: ...ur installation technician to find out the list of available buttons for your vehicle Enter PIN code While entering one of the PIN digits keep in mind that pressings duration and pauses be tween figur...

Страница 9: ...ce mode Quickly engaging maximum security Two circuit security mode increases the anti theft possibilities of the immobilizer system in case if the tag is stolen or lost Engage the second security cir...

Страница 10: ...ock control The system s anti thieft capabilities may be improved by installing an additional electro mechanical hood lock and programming the alarm to latch the hood when arming the vehicle and to un...

Страница 11: ...nt is described in the Table 3 Connectors pin numeration is shown in figure 1 Inputs outputs adjustment is carried out through the programming menu see section Hardware functions configuration 12 7 1...

Страница 12: ...pause 2 short beeps 4 sec The module will indicate the detected group and subgroup circularly 3 times Manual interfacing This interfacing method might be necessary only in exceptional cases A group a...

Страница 13: ...corresponding po larity and assign the feature 6 refer to the Table 7 to the programmable inputs These buttons may be used as the programming button or for entering a PIN code even if the resistive o...

Страница 14: ...n It is also possible to assign to these inputs any feature listed in the Table 7 if the option 6 is configured for the value 2 7 Hazard lights control method 4 1 by connecting to a pulse hazard light...

Страница 15: ...short beeps 25 two long and 5 short beeps It is allowed to enter PIN code 2 with the programming button if a vehicle hasn t yet travelled 10 km after the installation and the default PIN code hasn t b...

Страница 16: ...yellow 9 wires configuration CAN bus or Output 1 1 data bus CAN2 2 programmable output 5 Brown wire 3 function configu ration This wire function is dependant on the value of the option 4 Data bus CAN2...

Страница 17: ...lowed to en ter PIN code 2 with the programming button if a vehicle hasn t yet travelled 10 km after the installation and the default PIN code hasn t been changed The immobilizer system will automatic...

Страница 18: ...monitoring If it is not possible to read the Ignition status data out of the vehicle s CAN bus for exam ple when a vehicle s specific electrical circuits are being interrupted then this immobilizer i...

Страница 19: ...en only those doors you may do it beforehand that are supposed to be indicated on that output the doors you don t want to be indicated should be closed Apply the brake pedal again and keep it pressed...

Страница 20: ...ed if the engine is running and the vehicle s speed is less than 15 km h Yes 18 Rear parking sensors control power supply A constant level signal is formed if the engine is running the gear lever is s...

Страница 21: ...immobilizer is interfaced with a vehicle but also may be programmed manually if needed Yes 34 CDL unlocking alternative control A pulse is formed to unlock the power door locks with a double wire cont...

Страница 22: ...on hereinafter referred to as PB The immobilizer emits audible signals hereinafter beeps to indicate the current state of a setting being programmed In case if the option number or the option value co...

Страница 23: ...system s memory 5 To delete the smartphone tags from memory still hoding the brake pedal down press and release the programming button 1 time the confirmation trill followed after that signifies that...

Страница 24: ...ll immobilizer features to the default settings In case if the immobilizer is not installed on a vehicle The reset can be carried out in 3 ways 1 Using the built in button provided that the factory PI...

Страница 25: ...ing procedure for a certain car may be found out in the Integrator https int tecel ru 5 Change the factory PIN code 6 Inform the vehicle s owner which particular button has been assigned as the progra...

Страница 26: ...ure allows to quickly analyze the data available on the vehicle s CAN bus and adjust connection scheme if required The built in LED is used for indication check The immobilizer connection diagram The...

Страница 27: ...rizrak 5S BT Mark in the picture the immobilizer ele ments installation place This may help to quickly find them later The immobilizer elements installation scheme in a vehicle Keep this scheme out of...

Страница 28: ...ble beeps hereinafter beeps It is allowed to enter PIN code 2 with the programming button if a vehicle hasn t yet travelled 10 km after installing the system and the default PIN code hasn t been chang...

Страница 29: ...ation adjustment 3 Output 4 1 alert warning signals to siren 2 en gine locking normally closed NC relay control 3 programmable output refer to the option 8 4 electromechanical hood lock latching 8 The...

Страница 30: ...luetooth using an adapter TEC prog USB Bluetooth and follow the displayed instructions Cancelling registration if the main Immobilizer module is not available 1 Disconnect the module from power 2 Conn...

Страница 31: ...1 Quick reference card 1 Owner s guide 1 Warranty card 1 Wiring diagram 1 Packing 1 Technical specifications and operating conditions Parameter Value Power supply voltage V 9 15 Maximum current drain...

Страница 32: ...www tecel ru...

Отзывы: