Programming sequence
The programming process is carried out through the programming button (hereinafter — PB). The immobilizer
emits audible beeps during the programming process to indicate correctness of the actions being performed (here-
inafter — beeps). In case if an option number or a value number consists of a two digit number then it will be indi-
cates as follows: the first digit
—
a long beep, the second digit
—
a short beep. As an example: 12
—
one long beep,
two short beeps; 25 —
two long beeps, five short beeps. Do not allow more than 10 seconds to lapse between the
steps when the brake pedal is not pressed or the programming mode will be automatically exited and you will have
to start over. The programming mode will also be cancelled if at any step the ignition is switched off.
1.
Switch the vehicle’s ignition to the ON position. Complete authentication procedure.
2.
Within 10 seconds press the programming button 20 times, the immobilizer system will indicate that the
correct menu has been successfully entered by emitting 10 beeps and LED flashes.
3.
Select a desired option within the menu by pressing and releasing the programming button the number of
times corresponding to the option number. The immobilizer system will indicate the selected option number
by a series of beeps and LED flashes.
4.
Verify the current value of the selected option by pressing and holding the brake pedal, The system will
indicate the current option value by a series of beeps and LED flashes, the beeps length will change.
5.
To change the current value of the option: still holding the brake pedal down press the programming button
a required number of times. The number of the option value increases by 1 each time the button is pressed.
6.
If you’d like to program another option of the menu-release the brake pedal. You will get baсk to the step №3.
If you’d like to exit the programming menu - simply switch OFF the ignition.
Cancelling registration
of the HCU-230/BT module
The procedure may be useful in case if the already installed HCU module is planned to be paired with another
(new) immobilizer system. After the «Cancelling registration of the HCU-230 module» procedure has been
completed, it is possible to re-register the module into another immobilizer system. This procedure doesn’t reset
the HCU module to defaults. To reset the HCU module to defaults — carry out the «Resetting to default values»
procedure in the Prizrak system menu.
Cancelling registration
using the TECprog2
Launch the TECprog2 software on your PC, connect the immobilizer system to the computer via a USB cable or
via Bluetooth (using an adapter TEC-prog USB Bluetooth) and follow the displayed instructions.
Cancelling registration
if the main Immobilizer module is not available
1.
Disconnect the module from power.
2.
Connect the input/output №2 and input/output №5 to the vehicle’s «ground».
3.
Supply power to the module.
4.
Disconnect the input/output №2 and Input/output №5 from the vehicle’s «ground».
5.
Within the next 10 seconds supply 5 negative pulses to the module input/output №2 and Input/output №5.
Cancelling registration
of the HCU-230 module through the main module’s programming menu
Both devices (the immobilzer module and the HCU-230) have to be installed on a vehicle and supplied with +12 V.
The programming process is carried out through the programming button (hereinafter — PB). The immobilizer
emits audible beeps during the programming process to indicate correctness of the actions being performed
(hereinafter — beeps). In case if an option number or a value number consists of a two digit number then it will
be indicated as follows: the first digit
—
a long beep, the second digit
—
a short beep. As an example: 12
— one
long beep, two short beeps; 25
—
two long beeps, five short beeps. Do not allow more than 10 seconds to lapse
between the steps when the brake pedal is not pressed or the programming mode will be automatically exited and
you will have to start over. The programming mode will also be cancelled if at any step the ignition is switched off.
The system emits a long warning beep if an error occurs during the registration void process. You will have to start over.
1.
Turn the vehicle’s ignition ON and complete an authentication procedure (enter PIN code and/or wait until a
tag is detected) — confirmation trill will sound.
2.
Enter the menu «Hood compartment unit HCU-230/BT adjustment» within 10 seconds after authentication
is complete by pressing and releasing the programming button 20 times. The system will emit 11 beeps and
flash the LED 11 times to confirm that the menu has been successfully entered.
3.
Select the option №3 «Hood compartment unit HCU-230/BT registration» by pressing and releasing the
programming button 3 times. The system will indicate the selected option number by a series of 3 beeps
and 3 LED flashes.
4.
Press and hold the brake pedal. The system will indicate if any hood compartment module has already been
registered into the main immobilizer module:
•
one beep and one LED flash — an HCU module has already been registered;
•
silence — no module registered.
5.
Press the programming button 1 time, the system will inform about the start of the void process by short
intermittent beeps.
6.
The confirmation beep will sound if the registration is successfully void. Hereafter you may exit the
programming menu by switching the vehicle’s ignition OFF.
7.
To finish the procedure — release the brake pedal and switch OFF the ignition.
Содержание Prizrak 5S/BT
Страница 1: ...PROTECTION AGAINST PROFESSIONAL CARJACKING IMMOBILIZER TECHNICAL DESCRIPTION...
Страница 32: ...www tecel ru...